Quality control test for electronic portal imaging device using QC-3 phantom with PIPSpro

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
5
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 15 publications
1
5
0
Order By: Relevance
“…Gd2O2S:Tb is utilized in EPID systems [2], [11], [12] since it efficiently absorbs the X-ray photons and converts the absorbed X-ray energy to optical photon energy. The optical photons that escape the phosphor part of the EPID are subsequently absorbed into the silicon pixelated array and finally converted to bit values.…”
Section: Optical Photons Creation and Propagationmentioning
confidence: 99%
See 1 more Smart Citation
“…Gd2O2S:Tb is utilized in EPID systems [2], [11], [12] since it efficiently absorbs the X-ray photons and converts the absorbed X-ray energy to optical photon energy. The optical photons that escape the phosphor part of the EPID are subsequently absorbed into the silicon pixelated array and finally converted to bit values.…”
Section: Optical Photons Creation and Propagationmentioning
confidence: 99%
“…The assessment of the imaging performance of an EPID is performed with dedicated phantoms and methods as part of the quality control procedure [9], [10]. The phantoms may contain areas of low and high atomic number materials of different shapes so that parameters like image contrast, resolution and noise, to be evaluated [11], [12]. In this work the first step in the design of a phantom for image contrast assessment is presented.…”
Section: Introductionmentioning
confidence: 99%
“…The QC3 phantom integrated with PIPSpro™ software (Standard Imaging, Middleton, WI) is the other popular QA tool. 35 It contains a series of high-contrast bar patterns with spatial frequencies of 0.1, 0.2, 0.25, 0.4, and 0.75 lp/mm and six uniform regions made from lead, aluminum, or plastic of different thicknesses. In measurement, the phantom was placed on the surface of the EPID detector at 45 • angle with respect to the axis to prevent spatial aliasing.…”
Section: D Sensitivity Analysismentioning
confidence: 99%
“…For the patient specific pretreatment quality assurance for s-IMRT, d-IMRT and VMAT were performed systematically twice with 2D array (PTW, Freiburg) and a-Si EPID. [21][22][23][24] These detectors worked in the integrated mode, so the fluence delivered with each and every beam and segment was accumulated in a single frame. The measured fluence was compared with the TPS calculated fluence.…”
Section: Treatment Planning Optimization and Pre-treatment Verificatmentioning
confidence: 99%
“…It is a popular tool amongst the modern quality control techniques. [18][19] Besides positional verification [20][21] and quality control of linac 19,[22][23]24 , several studies have validated a-Si EPID for patient specific dosimetry.…”