2020
DOI: 10.1016/j.nima.2020.164521
|View full text |Cite
|
Sign up to set email alerts
|

Quality Assurance methodology for the ATLAS Inner Tracker strip sensor production

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(10 citation statements)
references
References 12 publications
0
9
0
Order By: Relevance
“…In this case, only non-irradiated and gamma-irradiated capacitors are measured (proton-and neutron-irradiated capacitors were too damaged to extract post-irradiation parameters). Inter-strip capacitance (C int ) and resistance (R int ) are obtained by direct measurement from interdigitated structures [2]. R int results (figure 3(b)) fulfil the specifications (R int > 15 MΩ).…”
Section: Results and Analysismentioning
confidence: 68%
See 2 more Smart Citations
“…In this case, only non-irradiated and gamma-irradiated capacitors are measured (proton-and neutron-irradiated capacitors were too damaged to extract post-irradiation parameters). Inter-strip capacitance (C int ) and resistance (R int ) are obtained by direct measurement from interdigitated structures [2]. R int results (figure 3(b)) fulfil the specifications (R int > 15 MΩ).…”
Section: Results and Analysismentioning
confidence: 68%
“…In this paper, we focus on the Testchip and the MD8 test devices (figure 1) [2], and the analysis of the parameters measured for each one of these devices before and after neutron, proton or gamma irradiation. The ATLAS Testchip contains test structures to monitor specific deviceelement parameters.…”
Section: Description Of the Main Devicesmentioning
confidence: 99%
See 1 more Smart Citation
“…One QA type, called "Mini & MD8", also contains a miniature strip sensor for measuring the signal size. Another one, called "TestChip & MD8", has a test chip with several structures for measuring technological parameters [10].…”
Section: Database Objectsmentioning
confidence: 99%
“…It is performed on the main sensors, which will be used in the ITk detector, and includes tests on every sensor (visual inspection, IV, CV and metrology) and tests on sample sensors (leakage current stability, full strip tests and detailed strip tests). QA includes the tests performed on miniature sensors and test structures before irradiation, the irradiation itself and tests after irradiation, of such components sampled from every production batch to provide confidence that the requirements are fulfilled through the whole production [4]. A summary of the participating QC and QA testing sites can be found in the Table 1…”
Section: Quality Assessment Programmentioning
confidence: 99%