Qualitative assessment of attributes and ease of use of the ELLIPTA™ dry powder inhaler for delivery of maintenance therapy for asthma and COPD

Abstract: BackgroundMedications for respiratory disorders including asthma and chronic obstructive pulmonary disease (COPD) are typically delivered to the lung by means of a handheld inhaler. Patient preference for and ability to use the inhaler may influence their adherence to maintenance therapy, and adherence may affect treatment outcomes. In this study, patient experience of using a dry powder inhaler (DPI), the ELLIPTA™ DPI, in clinical trials of a new maintenance therapy for asthma and COPD was investigated. The E… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

4
52
0
7

Year Published

2014
2014
2018
2018

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 75 publications
(63 citation statements)
references
References 32 publications
4
52
0
7
Order By: Relevance
“…system was associated with high patient satisfaction and was preferred over other systems in 75 patients with COPD and asthma aged 18 years and over [Svedsater et al 2013]. At the time of survey, 44 of the 75 patients were on DISKUS (GlaxoSmithKline, England) inhalers or the DISKUS and Handi-Haler (Boehringer Ingelheim, Germany) systems.…”
Section: Tolerability Of Inhaled Ff/vimentioning
confidence: 99%
“…system was associated with high patient satisfaction and was preferred over other systems in 75 patients with COPD and asthma aged 18 years and over [Svedsater et al 2013]. At the time of survey, 44 of the 75 patients were on DISKUS (GlaxoSmithKline, England) inhalers or the DISKUS and Handi-Haler (Boehringer Ingelheim, Germany) systems.…”
Section: Tolerability Of Inhaled Ff/vimentioning
confidence: 99%
“…Of note, the NEXThaler is the only DPI delivering extra-fine particles and this unique characteristic depends on specific physicochemical properties of the powder formulation, as well as on the innovative de-aggregation release system [36]. The Ellipta is a multi-unit DPI which includes a dose counter; a recent exploratory study has shown that several attributes of the Ellipta, such as ease of use and simplicity of operation, the visibility and ease of interpretation of the dose counter, the feel and fit of the inhalation mouthpiece, and design ergonomics, are viewed positively by asthma and COPD patients [37]. Noticeably, the Ellipta was preferred to other inhalers by interview participants with asthma and COPD [37].…”
Section: ‘The Good' : Innovations In Pulmonary Drug Delivery Systemsmentioning
confidence: 99%
“…Наиболее частыми ошибками применения ПИ Эллипта были неправильные снятие крышки (1,9 %), ингаляция лекарства (1,4 %) и закрывание крышки (0,3 %) [11]. В последующем целенаправленно изучалось отно шение больных к новому ПИ; обобщен опыт приме нения этого ПИ больными ХОБЛ и бронхиальной астмой (БА), участвовавшими в клинических ис следованиях [12]. В течение 4 нед.…”
unclassified
“…При сравнении с ранее применявшимися ПИ 95 % больных предпочли ПИ Эллипта ХандиХалеру, 79 % -Мультидиску и 77 % -дозированным аэрозольным ингаляторам [12].…”