Conference Record of the Twenty Fifth IEEE Photovoltaic Specialists Conference - 1996 1996
DOI: 10.1109/pvsc.1996.564424
|View full text |Cite
|
Sign up to set email alerts
|

PVUSA-the first decade of experience

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

1997
1997
2011
2011

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 3 publications
0
7
0
Order By: Relevance
“…and cos c S ¼ ðsin g s sin f À sin dÞ=ðcos g s cos fÞ (3) where d, f and v are, respectively, the latitude, the declination and the hour angles.…”
Section: Tracking Geometrymentioning
confidence: 99%
See 1 more Smart Citation
“…and cos c S ¼ ðsin g s sin f À sin dÞ=ðcos g s cos fÞ (3) where d, f and v are, respectively, the latitude, the declination and the hour angles.…”
Section: Tracking Geometrymentioning
confidence: 99%
“…1 The available literature describes several cases with good performance in terms of both reliability and energy gains. [2][3][4][5][6][7][8][9][10][11][12][13][14][15] Typical costs of PV grid-connected systems at current Spanish market are around 5s/Wp for static arrays (3s/Wp for PV modules plus wiring, 0Á5s/Wp for support structure plus civil works, 0Á5s/Wp for inverters and 1s/Wp for others) and 6s/Wp for two-axes tracking (support structure plus civil works are now 1, 5s/Wp). Then, investment increase is about 20% while energy yield increase is about 40%.…”
Section: Introductionmentioning
confidence: 99%
“…The PVUSA plan in the United States consisted of a number of concentrator prototypes that were installed and measured, 24 but they all were small installations hardly representative of a real plant. Some efficiencies recorded from this experience are detailed in Figure 9.…”
Section: Systems Experiencementioning
confidence: 99%
“…. 24 It allows concentrator (ENTECH and AMONIX) and non-concentrator (the rest) performances to be compared…”
Section: Manufacturingmentioning
confidence: 99%
“…High reliability and low maintenance requirements have been demonstrated in several practical projects. [1][2] The Toledo PV Plant, for example, where a 1000-m 2 tracking system has been in routine operation since July 1994, with 100% availability. This can be interpreted as a mean time between failures below 60 000 h, which speaks for itself.…”
Section: Introductionmentioning
confidence: 99%