2007
DOI: 10.1016/j.snb.2007.02.002
|View full text |Cite
|
Sign up to set email alerts
|

PVDF coated quartz crystal microbalance sensor for DMMP vapor detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
40
1

Year Published

2008
2008
2023
2023

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 86 publications
(42 citation statements)
references
References 31 publications
1
40
1
Order By: Relevance
“…For example, a poly(vinylidene fluoride) (PVDF)-coated quartz crystal microbalance sensor has a calculated LOD of 0.94 ppm [31] ; a chemicapacitor filled with siloxanefluoro alcohol (SXFA) has demonstrated a lowest detected concentration of 0.18 ppm and a calculated LOD of 2 ppb [32] ; and the calculated LOD for a single-walled carbon nanotube capacitor coated with a thin polycarbosilane coating is 0.5 ppb. [33] …”
Section: Response Of the Double-stack Sensor To Nerve Agent Simulantmentioning
confidence: 99%
“…For example, a poly(vinylidene fluoride) (PVDF)-coated quartz crystal microbalance sensor has a calculated LOD of 0.94 ppm [31] ; a chemicapacitor filled with siloxanefluoro alcohol (SXFA) has demonstrated a lowest detected concentration of 0.18 ppm and a calculated LOD of 2 ppb [32] ; and the calculated LOD for a single-walled carbon nanotube capacitor coated with a thin polycarbosilane coating is 0.5 ppb. [33] …”
Section: Response Of the Double-stack Sensor To Nerve Agent Simulantmentioning
confidence: 99%
“…Several studies dealing with QCM sensors have presented a very good linear correlation in frequency shift versus concentrations of target substances within a specific range [27][28][29]. In this study, the linearity in the frequency-shift rate versus solution concentration was evaluated using different concentrations of palmitic acid solutions at pH 10.7.…”
Section: Linear Range and Selectivity Of The Sensormentioning
confidence: 99%
“…Jiang and coworkers prepared a polymer film-coated quartz resonator for detecting dimethyl methylphosphonate (DMMP) vapor as a stimulant of nerve agents. The polyvinylidene fluoride (PVDF) film-coated quartz resonator was found to be sensitive to DMMP vapor at 5-60 ppm with a rapid and reversible response (Ying et al, 2007). A zeolite film was also utilized as a coating of QCM for detecting DMMP (Xie et al, 2005).…”
Section: Miscellaneous Biosensors For Op Detectionmentioning
confidence: 99%