2016
DOI: 10.1016/j.ijom.2015.11.024
|View full text |Cite
|
Sign up to set email alerts
|

Pure orbital blowout fractures reconstructed with autogenous bone grafts: functional and aesthetic outcomes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
18
0
2

Year Published

2016
2016
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(21 citation statements)
references
References 29 publications
1
18
0
2
Order By: Relevance
“…Bone, cartilaginous and fascial autografts are the most suitable materials for orbital floor reconstruction due to their non-allergenic and non-carcinogenic nature, and also high biocompatibility. [12,13] However, there are disadvantages of using autografts, such as increased duration of surgery, donor site morbidity, difficulties in shaping the graft and unpredictable graft resorption rate. [13,14] Alloplastic implants are consistent synthetic materials.…”
Section: Discussionmentioning
confidence: 99%
“…Bone, cartilaginous and fascial autografts are the most suitable materials for orbital floor reconstruction due to their non-allergenic and non-carcinogenic nature, and also high biocompatibility. [12,13] However, there are disadvantages of using autografts, such as increased duration of surgery, donor site morbidity, difficulties in shaping the graft and unpredictable graft resorption rate. [13,14] Alloplastic implants are consistent synthetic materials.…”
Section: Discussionmentioning
confidence: 99%
“…Engineering techniques, including a rapid prototyping (RP) model, a mirrored patient-specific implant (PSI), and 3D printing technology, have been introduced in medicine to obtain a more precise implant contour (Hassfeld & Muhling, 2001;Metzger et al 2006;Lieger et al 2010;Stoor et al 2014;Kozakiewicz, 2014;Gander et al 2015;Oh et al 2016;Cha et al 2017;Kim et al 2017;Vignesh et al 2017) RP and a mirrored PSI are highly applicable to surgery because they easily produce a complex structure similar to an orbital cavity. Aseptic treatment of the RP contour model is followed by intra-operative molding and bending of the implant material, such as titanium, to obtain a customized implant with a precise contour that is applied at the fracture site (Vehmeijer et al 2016;Kronig et al 2016;Oh et al 2016;Kim et al 2017). A mirrored PSI is obtained by 3D reconstruction of the fractured orbit using the mirrored normal orbit as a template (Gander et al 2015).…”
Section: Discussionmentioning
confidence: 99%
“…Nos casos em que a cirurgia é indicada, alguns materiais podem ser utilizados para reconstrução da órbita, variando entre enxertos e materiais aloplásticos. Kronig et al 4 (2016) realizaram um estudo com a reconstrução feita com enxerto ósseo autógeno e observaram que, com seguimento de um ano, nenhum dos pacientes submetidos ao procedimento apresentou enoftalmo, quando todas as paredes envolvidas foram reconstruídas; já, nos pacientes que não tiveram a parede medial reconstruída, 29% ainda apresentavam enoftalmo após o período de tempo.…”
Section: Discussionunclassified
“…Os pacientes que apresentam fraturas de órbita costumam ter como sinais clínicos o edema e a equimose periorbitários, assimetria das órbitas, limitação da motilidade ocular, ptose palpebral, enoftalmo e hipoftalmo. É recorrente, também, que os pacientes apresentem sintomas como parestesia na região infraorbitária e diplopia 4 .…”
Section: Introductionunclassified