1995
DOI: 10.1006/jmra.1995.9977
|View full text |Cite
|
Sign up to set email alerts
|

Pulsed Transient Nutation Experiments of the Photo-Excited Triplet State

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
10
0

Year Published

1998
1998
2017
2017

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 15 publications
(12 citation statements)
references
References 5 publications
(12 reference statements)
2
10
0
Order By: Relevance
“…Here the Rabi frequency of the electron spin system (rotating frame in the preparation pulse) was made to approximately match the Lamor frequency of the nuclear system (laboratory frame) to fulfill the Hartmann-Hahn condition for an effective polarization transfer. Previously, we have also observed similar effects in the pulsed transient nutation experiments where the spectral diffusion and polarization transfer processes in the LF transition are one order of magnitude greater than those of the HF transition (10). The effective polarization transfer in the LF transition is attributed to the substantial contribution from the nonsecular hyperfine terms.…”
Section: Figsupporting
confidence: 53%
See 2 more Smart Citations
“…Here the Rabi frequency of the electron spin system (rotating frame in the preparation pulse) was made to approximately match the Lamor frequency of the nuclear system (laboratory frame) to fulfill the Hartmann-Hahn condition for an effective polarization transfer. Previously, we have also observed similar effects in the pulsed transient nutation experiments where the spectral diffusion and polarization transfer processes in the LF transition are one order of magnitude greater than those of the HF transition (10). The effective polarization transfer in the LF transition is attributed to the substantial contribution from the nonsecular hyperfine terms.…”
Section: Figsupporting
confidence: 53%
“…A special ENDOR cavity with multiple-turn NMR coils wound around the sample was used in the measurement, which is similar to the setup used in the previous pulsed transient nutation experiments (10).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The maximal achievable B 1 amplitude was measured using an ESE-detected transient nutation experiment in which the transient nutation during a preparation pulse is monitored using a two-pulse ESE sequence (28). As follows from Fig.…”
Section: Performancementioning
confidence: 99%
“…Therefore, many modern homebuilt spectrometers operating at lower microwave frequencies (from S to K u band) were constructed as broadband instruments (15)(16)(17)(18)(19)(20)(21). Because our K a -band spectrometer was conceived with ESEEM applications in mind, it was logical for us to build it as a broadband instrument operating in the entire K a band (27)(28)(29)(30)(31)(32)(33)(34)(35)(36)(37)(38)(39)(40). Until recently, achieving such a goal would be next to impossible because many of the necessary broadband K a -band microwave components were not available commercially.…”
Section: Introductionmentioning
confidence: 99%