2019
DOI: 10.1016/j.ijrobp.2018.10.002
|View full text |Cite
|
Sign up to set email alerts
|

Pseudo-CT Generation for MRI-Only Radiation Therapy Treatment Planning: Comparison Among Patch-Based, Atlas-Based, and Bulk Density Methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
24
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 37 publications
(24 citation statements)
references
References 38 publications
0
24
0
Order By: Relevance
“…Kim et al [18] reported no significant dosimetric difference between continuous HU or bulk-HU sCTs but obtained higher gamma-index passing-rate of 97.2% vs. 94.0% for continuous sCT evaluated with 1%/1 mm gamma-criteria. Largent et al [17] found that the mean gamma-index pass-rate for continuous HU values (99.5%) was significantly higher than that of bulk density method (96.1%). Both Kim et al and Largent et al used only two bulk densities: one for bone and one for soft-tissue that could explain worse dosimetric agreement in comparison to our results.…”
Section: Discussionmentioning
confidence: 95%
See 1 more Smart Citation
“…Kim et al [18] reported no significant dosimetric difference between continuous HU or bulk-HU sCTs but obtained higher gamma-index passing-rate of 97.2% vs. 94.0% for continuous sCT evaluated with 1%/1 mm gamma-criteria. Largent et al [17] found that the mean gamma-index pass-rate for continuous HU values (99.5%) was significantly higher than that of bulk density method (96.1%). Both Kim et al and Largent et al used only two bulk densities: one for bone and one for soft-tissue that could explain worse dosimetric agreement in comparison to our results.…”
Section: Discussionmentioning
confidence: 95%
“…Several groups have assessed the dosimetric and positioning for prostate cancer with comparison of continuous HU and bulk HU assignment (see e.g. [16][17][18][19]). Two recent studies have evaluated the feasibility of MRI-only workflow for rectal cancers [20,21].…”
Section: Introductionmentioning
confidence: 99%
“…Application of automated bone segmentation on MRI may cause dosimetric inaccuracy for the BAD MR maps. More accurate segmentation can potentially be achieved via manual contouring however this is time consuming and the level of accuracy can vary depending on the level of expertise and experience of individuals (10, 30).…”
Section: Discussionmentioning
confidence: 99%
“…Different methods have been introduced to create sCT scans for prostate radiotherapy planning. Bulk-density planning was initially investigated as a method for sCT generation (510). These studies applied a density of water to the body with an additional separate density for bone.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation