2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe) 2017
DOI: 10.1109/isgteurope.2017.8260165
|View full text |Cite
|
Sign up to set email alerts
|

Provision of ancillary services in future low-carbon UK electricity system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
4

Relationship

2
6

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 7 publications
0
9
0
Order By: Relevance
“…For frequency to stabilise eventually after the fault, the amount of FR available must be at least equal to the power outage. In other words, the steady-state constraint is obtained by setting RoCoF to zero in (1) and considering that every FR service has been fully delivered:…”
Section: A Deducing Frequency-security Constraintsmentioning
confidence: 99%
See 2 more Smart Citations
“…For frequency to stabilise eventually after the fault, the amount of FR available must be at least equal to the power outage. In other words, the steady-state constraint is obtained by setting RoCoF to zero in (1) and considering that every FR service has been fully delivered:…”
Section: A Deducing Frequency-security Constraintsmentioning
confidence: 99%
“…The time within t ∈ [T n−1 , T n ) at which nadir is exactly reached is given by setting RoCoF to zero in (1) for that given time interval:…”
Section: A Deducing Frequency-security Constraintsmentioning
confidence: 99%
See 1 more Smart Citation
“…These services are normally provided by conventional generation units. Wind and solar generally do not participate in these services, but they will have to be included in these services in the future when their share becomes significant [14]. RES are spatially scattered and could be able to provide local services, either through local markets or through long-term contracts.…”
Section: Introduction 1motivation and Backgroundmentioning
confidence: 99%
“…In November 2019, with the recent surge in variable renewable energy generation capacity being added to the system (both small-scale rooftop PV and large-scale wind and solar), the instantaneous penetration of renewable energy in the system rose above 50% for the first time [2]- [4]. As a result, there has been a noticeable downward trend in synchronous generator inertia in the SWIS over the last few years (as shown in Fig.…”
Section: Introductionmentioning
confidence: 99%