“…The double dependency of heat pipes thermal resistance on the air flow and the heat flux is characterized and one prototype of heat pump is built (see Fig. 1, Left) and deeply analysed in [11] with the help of a climatic chamber, with different temperature gaps in air streams emulating all possible combinations in a building with different indoor and outdoor conditions. Main results are shown in next chapter (see Fig.…”
Section: Experimental Researchmentioning
confidence: 99%
“…The double dependency of heat pipes thermal resistance on the air flow and the heat flux is characterized and one prototype of heat pump is built (see Fig. 1, Left) and deeply analysed in [11] with the help of a climatic chamber, with different temperature gaps in air streams emulating all possible combinations in a building with different indoor and outdoor conditions. Main results are shown in next chapter (see Fig.…”
Section: Experimental Researchmentioning
confidence: 99%
“…found that the optimized system can achieve COP of 2.0 under test conditions and upto 3.0 for typical hot climate. Garayo et al 44 studied the design and application of airto-air thermoelectric heat pump for application in ventilation system of a passive solar house using 10 TEMs.…”
Section: Studies On Demonstration Of Thermoelectric Heating And/cooli...mentioning
confidence: 99%
“…Su et al 31 studied the application of TEM and RSC system and found that the optimized system can achieve COP of 2.0 under test conditions and upto 3.0 for typical hot climate. Garayo et al 44 studied the design and application of air‐to‐air thermoelectric heat pump for application in ventilation system of a passive solar house using 10 TEMs. Results showed that the system produced 1250 W for heating and 375 W for cooling with respective COPs in range of 1.5 to 4.0 and 0.5 to 2.5 depending on airflows, temperature gradient, and voltage supply.…”
Section: Application Of Tem For Heating or Cooling Of Buildingsmentioning
confidence: 99%
“…Also, TEAC with 5 more than twenty TEMs will increase the energy consumption, attributed to less COP. In 2021, Garayo et al [24] optimized the COP of a thermoelectric cooling system with double flux mechanical ventilation in a house of 80 m 2 area. The authors emphasized the significance of airflows, voltage supply, and temperature gaps attributed to a maximum cooling capacity and COP of 375W and 2.5.…”