Protection collaborative fault control for power electronic-based power plants during unbalanced grid faults

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
30
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
2
2

Relationship

2
6

Authors

Journals

citations
Cited by 22 publications
(32 citation statements)
references
References 12 publications
1
30
0
Order By: Relevance
“…In the diamond-shaped distribution network connection, the incoming and outgoing lines of the ring network room are equipped with full circuit breakers and full protection. On the one hand, it can avoid the change of relay protection (Ma et al, 2021) caused by the access of new elements such as distributed power sources and microgrids. On the other hand, it can solve the problem that the fuse curve of the fuse of the access point of largecapacity users is difficult to match with the zero-sequence current protection setting value, and meet the access needs of largecapacity users.…”
Section: Adaptability Security and Flexibility Analysismentioning
confidence: 99%
“…In the diamond-shaped distribution network connection, the incoming and outgoing lines of the ring network room are equipped with full circuit breakers and full protection. On the one hand, it can avoid the change of relay protection (Ma et al, 2021) caused by the access of new elements such as distributed power sources and microgrids. On the other hand, it can solve the problem that the fuse curve of the fuse of the access point of largecapacity users is difficult to match with the zero-sequence current protection setting value, and meet the access needs of largecapacity users.…”
Section: Adaptability Security and Flexibility Analysismentioning
confidence: 99%
“…Subscripts 1 and 2 denote the positive-and negative-sequence components during the fault, and b denotes the electric quantities before the fault. In general, the electric quantities before the fault only include positive-sequence components [17], so Δ𝑈 ̇2 in (4) is equal to 𝑈 ̇2. According to the reference positive direction from the busbar to the line, the impedance angle detected by directional relays should approach -90° for forward faults in the traditional grid [9].…”
Section: B the Performance Of Psfcbdrs And Nsdrsmentioning
confidence: 99%
“…When current references are set according to (17), PSFCBDRs can operate correctly since the impedance angle seen by them will be close to -90°.…”
Section: A Positive-sequence Current Referencesmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to calculate reasonable current references in (17) and (22), suitable initial values of the I1m and I2m must be given considering the current limiting of the inverter. Assumed that negative-sequence current is β times the positive-sequence current, ( 23) can be obtained:…”
Section: Initial Setting Of Positive-sequence Currentmentioning
confidence: 99%