2010
DOI: 10.2214/ajr.09.3739
|View full text |Cite
|
Sign up to set email alerts
|

Prospective Study of Access Site Complications of Automated Contrast Injection With Peripheral Venous Access in MDCT

Abstract: Automated IV contrast injection applying high flow rates (i.e., up to 8 mL/s) is performed without increased risk of extravasation. The overall extravasation rate was 1.2% and showed no correlation with iodine concentration, flow rates, or contrast material reactions. Performing high flow rates with low-diameter IV catheters (e.g., 22-gauge catheters) and a location of IV catheter in the hand is associated with a higher extravasation rate.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
71
4
4

Year Published

2011
2011
2018
2018

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 68 publications
(89 citation statements)
references
References 23 publications
5
71
4
4
Order By: Relevance
“…Most published series suggest an extravasation rate of less than 1% for intravenous injection of iodinated contrast media for CT scanning. 11,12 Most contrast extravasations are small volume, and symptoms resolve with conservative treatment. Unfortunately, the ultimate degree of injury cannot be determined at initial examination.…”
Section: Intravascular Contrast Administrationmentioning
confidence: 99%
“…Most published series suggest an extravasation rate of less than 1% for intravenous injection of iodinated contrast media for CT scanning. 11,12 Most contrast extravasations are small volume, and symptoms resolve with conservative treatment. Unfortunately, the ultimate degree of injury cannot be determined at initial examination.…”
Section: Intravascular Contrast Administrationmentioning
confidence: 99%
“…However, the occurrence of extravasation is not declining, only the incidence of consequential damage, meaning that severe complications in the form of tissue necrosis and compartment syndrome can still occur even after extravasation in small volumes [41,42]. Since there are no clear risk criteria for the development of complications with serious consequences, and since these cases are rarities, it is important to remain vigilant with all contrast medium extravasations and to regularly check the incidence in your own department in order to eliminate possible sources of risk.…”
Section: Discussionmentioning
confidence: 99%
“…Confirmation of reflux from the injection route has been reported as a safety countermeasure during power injection [3,[9][10][11]. In some reports, the saline test injection was performed manually [2,3,12].…”
Section: Discussionmentioning
confidence: 99%