2013
DOI: 10.1371/journal.pone.0065025
|View full text |Cite
|
Sign up to set email alerts
|

Prospective ECG-Triggered Coronary CT Angiography: Clinical Value of Noise-Based Tube Current Reduction Method with Iterative Reconstruction

Abstract: ObjectivesTo evaluate the clinical value of noise-based tube current reduction method with iterative reconstruction for obtaining consistent image quality with dose optimization in prospective electrocardiogram (ECG)-triggered coronary CT angiography (CCTA).Materials and MethodsWe performed a prospective randomized study evaluating 338 patients undergoing CCTA with prospective ECG-triggering. Patients were randomly assigned to fixed tube current with filtered back projection (Group 1, n = 113), noise-based tub… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
16
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(16 citation statements)
references
References 21 publications
0
16
0
Order By: Relevance
“…Dose‐length‐product values generally corresponded to CTDI vol as they are derived from multiplying CTDI vol with scan length (cm). Four studies did not report the DLP . The DLP for FBP is significantly higher (426 ± 226 mGy.cm) than IR (241 ± 106 mGy.cm) with a difference in the mean ± SD of 186 ± 120 mGy.cm ( P = 0.019).…”
Section: Resultsmentioning
confidence: 94%
See 3 more Smart Citations
“…Dose‐length‐product values generally corresponded to CTDI vol as they are derived from multiplying CTDI vol with scan length (cm). Four studies did not report the DLP . The DLP for FBP is significantly higher (426 ± 226 mGy.cm) than IR (241 ± 106 mGy.cm) with a difference in the mean ± SD of 186 ± 120 mGy.cm ( P = 0.019).…”
Section: Resultsmentioning
confidence: 94%
“…Dose indicators (CTDI vol , DLP and E D ) were extracted from studies where available (Tables and ). Six studies did not provide CTDI vol values . CTDI vol for FBP ranged from 16.20 to 60.30 mGy while for IR was from 11.30 to 36.90 mGy.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Good quality CT coronary angiography has become widely available, and can be performed with radiation doses lower than 2 mSv [9]. Exposure to such a low quantity of radiation seems acceptable to minimize the risk of iatrogenic myocardial infarction caused by accidental damage to an aberrant coronary artery during aortic root replacement in these young patients.…”
Section: Dear Editormentioning
confidence: 99%