2013
DOI: 10.1109/tie.2012.2193858
|View full text |Cite
|
Sign up to set email alerts
|

Proposal of Three-Phase High-Frequency Transformer Isolation UPS Topologies for Distributed Generation Applications

Abstract: A family of double conversion three-phase uninterruptible power systems with power factor correction and high-frequency transformer (HFT) isolation topologies, are presented in this work. This might be a suitable alternative compared to large conventional UPS systems that are based upon bulky transformers that operate at the grid frequency. This system is commonly used to supply critical loads, but nowadays, due to the increasing interest in renewable energy integration and distributed generation (DG), it can … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 49 publications
(16 citation statements)
references
References 41 publications
0
15
0
1
Order By: Relevance
“…3 illustrates the structure of a first-order APF. The input-tooutput transfer function describing the dynamics of APF is shown in (2), where w f is the fundamental angular frequency.…”
Section: A Different Osg Techniquesmentioning
confidence: 99%
“…3 illustrates the structure of a first-order APF. The input-tooutput transfer function describing the dynamics of APF is shown in (2), where w f is the fundamental angular frequency.…”
Section: A Different Osg Techniquesmentioning
confidence: 99%
“…Generally, the CM component suppression strategies are based on the converter architecture [10]- [12], modulation strategy [13], [14], and CM filter [15], [16] [19], the wye connection point of the AC side filter capacitors [13], and connection of the DC-link capacitor midpoint and wye point of AC filter capacitors [20], [21], were proposed to be used as neutral line for three-leg converter. The neutral line can also be supplied by an additional leg [13], [22].…”
Section: Introductionmentioning
confidence: 99%
“…Since the bypass CM filter can avoid the aforementioned drawback, it is used for CM suppression in the hybrid grids in this paper. However, as the bypass filter is mainly used in single-phase [26] and three-phase three-wire system [21] [24] so far, the impacts from the unbalanced AC loads on the filter performances have not been studied. The mechanism and attenuation of the fundamental CM voltage caused by unbalanced AC loads are never considered.…”
Section: Introductionmentioning
confidence: 99%
“…[1]. Typically, the UPS provides unity power factor, high efficiency, high reliability, low cost, and continuous power supply, irrespective of the grid conditions [2][3][4].…”
Section: Introductionmentioning
confidence: 99%