2017
DOI: 10.1049/iet-gtd.2016.0406
|View full text |Cite
|
Sign up to set email alerts
|

Probabilistic load flow analysis of active distribution network adopting improved sequence operation methodology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(16 citation statements)
references
References 20 publications
0
16
0
Order By: Relevance
“…An EGH-IES composed of a 33-bus electricity network [26], an 11-node gas network [7] and a 13-node heating network [13] operating in the "electricity/gas following heat" mode is used as a test system to verify the proposed PEF analysis method. The configuration of the test system is shown in Figure 5.…”
Section: Test System Descriptionmentioning
confidence: 99%
See 1 more Smart Citation
“…An EGH-IES composed of a 33-bus electricity network [26], an 11-node gas network [7] and a 13-node heating network [13] operating in the "electricity/gas following heat" mode is used as a test system to verify the proposed PEF analysis method. The configuration of the test system is shown in Figure 5.…”
Section: Test System Descriptionmentioning
confidence: 99%
“…The original electricity/gas/heat loads in Refs. [7,13,26] are taken as the mean values, and the SDs of loads are set to be 5% of their mean values.…”
Section: Test System Descriptionmentioning
confidence: 99%
“…As shown in Figure 5, an IEEE-30 bus system is modified for simulation analyses. Nodes 14,15,16,17,18 are linked to a wind farm (WF), and the rated capacity of each WF is The correlation coefficient matrix of the five WFs is:…”
Section: The Setting Of Desired Rangementioning
confidence: 99%
“…However, these algorithms are not accurate enough for low sampling times. In Reference [16], a sequence method was applied to reduce the iteration times; however, correlation was not considered in this method. In Reference [17], a uniform sampling method was adopted to solve the correlation problem, but the Copula function became very complex when the correlation nodes exceeded two and vitally limited the computation efficiency.…”
Section: Introductionmentioning
confidence: 99%
“…In [20], a firstorder second-moment method (FOSMM) was applied to obtain the mean and standard deviation of load flow solutions. The sequence operation methodology [21] is one of the analytical methods. It has a great advantage in terms of efficiency by sequence operation.…”
Section: Introductionmentioning
confidence: 99%