2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe) 2012
DOI: 10.1109/isgteurope.2012.6465671
|View full text |Cite
|
Sign up to set email alerts
|

Probabilistic approach-based PMU placement for real-time power system vulnerability assessment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
25
0
1

Year Published

2014
2014
2018
2018

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 25 publications
(26 citation statements)
references
References 12 publications
0
25
0
1
Order By: Relevance
“…Similarly to the previous system, three types of relays have been modelled and included in this system: OSR, VR, and FR. Additionally, six PMUs have already located at buses 2,9,11,17,22, and 28, based on the results presented in [45]. The test system single-line diagram is depicted in Figure 21, which also includes the PMU location.…”
Section: Ieee New England 39-bus Test Systemmentioning
confidence: 99%
“…Similarly to the previous system, three types of relays have been modelled and included in this system: OSR, VR, and FR. Additionally, six PMUs have already located at buses 2,9,11,17,22, and 28, based on the results presented in [45]. The test system single-line diagram is depicted in Figure 21, which also includes the PMU location.…”
Section: Ieee New England 39-bus Test Systemmentioning
confidence: 99%
“…To achieve the complete observability of the given system, total 42 PMUs are required. The optimal locations for these PMUs are 6,8,11,12,14,16,17,19,20,22,23,25,26,29,31,32,34,36,37,41,42,44,45,46,47,48,49,51,52,56,57,58,59, 60, 61, 62, 63, 64, 65, 66, 67, and 68. Placing PMUs on these locations will make the system completely observable at least by two PMUs, even when single-transmission line or PMU is lost.…”
Section: Optimal Pmu Placementsmentioning
confidence: 99%
“…Real-time control of small-signal oscillations is also as important as real-time monitoring of small-signal oscillations. In literature, deterministic and probabilistic approaches for small-signal analysis were reported [17][18][19][20][21][22][23][24]. Robust damping controller using h-infinity, linear matrix inequality techniques have been widely used [17,18] for damping out inter-area oscillations.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Clustering approaches are used in the power system research in many applications such as operation and control applications [ 13 , 14 ], generators coherency identification [ 15 , 16 , 17 ], event location [18] , power system vulnerability assessment [19] , controlled islanding [20] and power system restoration [21] . Hierarchical Clustering [22] is applied in this paper to partition the power system network into specific zones that comprising the correlated system buses and identifying the optimal PMU location within each zone based on simple rules.…”
Section: Introductionmentioning
confidence: 99%