Primal and Dual Bregman Methods with Application to Optical Nanoscopy

Abstract: Measurements in nanoscopic imaging suffer from blurring effects modeled with different point spread functions (PSF). Some apparatus even have PSFs that are locally dependent on phase shifts. Additionally, raw data are affected by Poisson noise resulting from laser sampling and "photon counts" in fluorescence microscopy. In these applications standard reconstruction methods (EM, filtered backprojection) deliver unsatisfactory and noisy results. Starting from a statistical modeling in terms of a MAP likelihood e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
78
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 71 publications
(81 citation statements)
references
References 58 publications
1
78
0
Order By: Relevance
“…These are the cardiomyocytes believed by Krehl [18] to provide the driving force for ventricular emptying. Perhaps more importantly, the quantitative, as opposed to qualitative, observations we were able to make using an automated system that avoids the need for subjective interpretation [16] confirm that a significant proportion of cardiomyocytes are aligned in a transmural fashion across the ventricular walls [11]. These measurements provided no support for the notion that all cardiomyocytes are aligned in a virtually tangential fashion.…”
Section: Histological Findingsmentioning
confidence: 84%
See 2 more Smart Citations
“…These are the cardiomyocytes believed by Krehl [18] to provide the driving force for ventricular emptying. Perhaps more importantly, the quantitative, as opposed to qualitative, observations we were able to make using an automated system that avoids the need for subjective interpretation [16] confirm that a significant proportion of cardiomyocytes are aligned in a transmural fashion across the ventricular walls [11]. These measurements provided no support for the notion that all cardiomyocytes are aligned in a virtually tangential fashion.…”
Section: Histological Findingsmentioning
confidence: 84%
“…Fig. 3 The upper three rows of the figures show the distribution of helical angles (left hand panels) and transversely intruding angles (middle panels) as assessed using the computed tomographic images from the basal, middle, and apical thirds of the ventricular cone as measured using the computerderived system [16]. The right-hand panels show the location of the site of measurement relative to the long axis of the posterior ventricular wall (right panel).…”
Section: Computed Tomographymentioning
confidence: 99%
See 1 more Smart Citation
“…In this section we propose a strategy to deal with inexact solutions of the inner subproblems that preserve the convergence property of the iterative procedure. The crucial point of the proposed scheme is devising a suitable stopping criterion for the inner solver of subproblems (6). To explain this novel scheme, we recall the basic definition and some results about the ϵ-subgradient of a proper convex function.…”
Section: The Inexact Iterative Proceduresmentioning
confidence: 99%
“…In recent years, many researchers [8,9,10,12,13,18,22,28,32] study the TV minimization via solving the following saddle-point problem:…”
Section: Introductionmentioning