2019
DOI: 10.1001/jamainternmed.2019.1739
|View full text |Cite
|
Sign up to set email alerts
|

Prevalence and Cost of Care Cascades After Low-Value Preoperative Electrocardiogram for Cataract Surgery in Fee-for-Service Medicare Beneficiaries

Abstract: IMPORTANCE Low-value care is prevalent in the United States, yet little is known about the downstream health care use triggered by low-value services. Measurement of such care cascades is essential to understanding the full consequences of low-value care.OBJECTIVE To describe cascades (tests, treatments, visits, hospitalizations, and new diagnoses) after a common low-value service, preoperative electrocardiogram (EKG) for patients undergoing cataract surgery. DESIGN, SETTING, AND PARTICIPANTS Observational coh… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
108
0
3

Year Published

2019
2019
2021
2021

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 75 publications
(115 citation statements)
references
References 58 publications
(154 reference statements)
4
108
0
3
Order By: Relevance
“…9,32 One-third of physicians in our survey reported that the initial test in their most recently experienced cascade may not have been clinically appropriate: harms are unlikely to be offset by any benefits from testing in such cases. 2,10…”
Section: Discussionmentioning
confidence: 99%
“…9,32 One-third of physicians in our survey reported that the initial test in their most recently experienced cascade may not have been clinically appropriate: harms are unlikely to be offset by any benefits from testing in such cases. 2,10…”
Section: Discussionmentioning
confidence: 99%
“…This approach may misclassify testing performed for indications other than preoperative testing during the specified time period and may miss preoperative testing performed for a planned procedure that did not ultimately occur. 22 , 25 , 26 …”
Section: Methodsmentioning
confidence: 99%
“…26,29 A strength of this study is the use of EHR data to explore downstream impacts of a common nonindicated laboratory test within a large health system, similar to that which has been performed with other lowvalue care services. 47,48 We are not aware of other published studies that have examined downstream consequences of low-value vitamin D tests. Although individual chart review was not performed in this study, Isaac et al 40 recently observed only minor differences in low-value care services identified via automated EHR search and individual chart review.…”
Section: Quality Of Carementioning
confidence: 99%