2010
DOI: 10.1016/j.optcom.2009.11.052
|View full text |Cite
|
Sign up to set email alerts
|

Pressure dependence of small signal gain and saturation intensity of a gold-vapor laser using various buffer gases in gain medium

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 8 publications
0
10
0
Order By: Relevance
“…However, since the Doppler broadening is sufficiently greater than the pressure broadening linewidth for a typi cal CBL as well as a CVL, the amplifying medium can be assumed to be an inhomogeneous broadened gain medium. The g 0 (cm −1 ) and E S (µJ cm −2 ) can be calculated with a leastsquares fitting of the experimental data into the Hargrove equation given by [14,20,21]…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, since the Doppler broadening is sufficiently greater than the pressure broadening linewidth for a typi cal CBL as well as a CVL, the amplifying medium can be assumed to be an inhomogeneous broadened gain medium. The g 0 (cm −1 ) and E S (µJ cm −2 ) can be calculated with a leastsquares fitting of the experimental data into the Hargrove equation given by [14,20,21]…”
Section: Resultsmentioning
confidence: 99%
“…The CBL MOPA system consisted of two identical tubes with an inner diameter of 20 mm and a length of 48 cm. This is a similar setup to those in our previous works for CVL and GVL MOPAs [14,20,21]. Two identical cylindrical tubes were used as the oscillator and the amplifier and these were made of quartz with an inner diameter of 20 mm and an active gain length of 48 cm.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…M. Lima, Behrouzinia, & Khorasani, 2019;S. M. Lima, Behrouzinia, S., Salem, M.K., Elahei, M., Khorasani, K.,Dorranian, D. , (2017); Nezhad, Sajad, Behrouzinia, Salehinia, & Khorasani, 2010). In our previous work, the independencies of the amplifying parameters of CBL on the different amplifier tube length with identical diameter has been investigated, individually.…”
Section: Introductionmentioning
confidence: 99%
“…Meanwhile, in our previous works, we have observed the linear behavior of gain and saturation properties in terms of operating pressure at an interval of 25-75 Torr of the CVL amplifying medium, [12] and at an interval of 14-30 Torr of the GVL amplifying medium. [14] The difference of behavior of amplifying parameters between CBL and CVL/GVL versus pressure can be related to the interval of operational pressure and may be related to the presence of third body (Br atoms) in the gain medium. Finally, the behavior of output power versus buffer gas pressure is shown in Fig.…”
mentioning
confidence: 99%