2006
DOI: 10.1016/s1003-9953(06)60015-7
|View full text |Cite
|
Sign up to set email alerts
|

Preparation of Small Particle Sized ZnAl-Hydrotalcite-Like Compounds by Ultrasonic Crystallization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
2
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 46 publications
(4 citation statements)
references
References 1 publication
2
2
0
Order By: Relevance
“…Earlier research shows that the crystallinity of the sample decreases with increasei n cerium due to the larged istortion introduced in the layers because of the ionic radii. [30] The XRD patterns of MeCe-HDC are identicalt ot he reference data of Mg(OH) 2 and CeCO 3 OH shown in Figure 3, confirming the presence of Mg(OH) 2 and CeCO 3 OH in the material. Mg(OH) 2 is present in aH exagonal form in the material with characteristic peaks at 18.65 (001), 32.81 (100), 38.01 (011), 58.…”
supporting
confidence: 69%
“…Earlier research shows that the crystallinity of the sample decreases with increasei n cerium due to the larged istortion introduced in the layers because of the ionic radii. [30] The XRD patterns of MeCe-HDC are identicalt ot he reference data of Mg(OH) 2 and CeCO 3 OH shown in Figure 3, confirming the presence of Mg(OH) 2 and CeCO 3 OH in the material. Mg(OH) 2 is present in aH exagonal form in the material with characteristic peaks at 18.65 (001), 32.81 (100), 38.01 (011), 58.…”
supporting
confidence: 69%
“…[16] As the LDH syntheses were performed by simultaneous dropping the metal salts and the alkaline solutions at constant pH 9, the supersaturation is probably low and, therefore, the small crystallites could be attributed to the ultrasound treatment. [17] Besides, the XRD patterns reported in Fig. 1(a) reveal a lower crystallinity of Mg-than Zn-containing LDH clays, in accordance with the behavior generally reported in the literature.…”
Section: Materials Characterizationsupporting
confidence: 89%
“…The samples synthesized with a metallic molar ratio of 3 presented more regular 00l peaks, independent of the synthesis method (Rivera et al , 2006; Xie et al , 2006). By contrast, samples crystallized in the presence of microwaves or ultrasound at molar ratios of 2 or 4 show two maxima in the 003 and 006 peaks or a shoulder at the right-hand side of the 003 peak.…”
Section: Resultsmentioning
confidence: 99%