2008
DOI: 10.1016/j.memsci.2007.10.024
|View full text |Cite
|
Sign up to set email alerts
|

Preparation of poly(vinylidene fluoride) microfiltration membrane with uniform surface-copolymerized poly(ethylene glycol) methacrylate and improvement of blood compatibility

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
53
0
1

Year Published

2008
2008
2022
2022

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 146 publications
(58 citation statements)
references
References 23 publications
1
53
0
1
Order By: Relevance
“…PLA film showed characteristically high water contact angles (79°± 2°), as expected, while the water contact angle decreases with higher PEG content in the triblock copolymer films. This result is similar to that of many studies using PEG as a surface modifier [45,46]. It is interesting to note that the water contact angle of PLA/PEG physical blend film with PEG content of 50% (w/w) is 33.5°± 2°; while the PLA-PEG-PLA triblock copolymer films had a relatively high initial water contact angle of 55°± 5°(measured at 10 sec after water-film contact), a) The number after the 'PEG' denotes the PEG content (in percentage) in each copolymer.…”
Section: Hydrophilicity Of the Pla-peg-pla Triblock Copolymerssupporting
confidence: 92%
“…PLA film showed characteristically high water contact angles (79°± 2°), as expected, while the water contact angle decreases with higher PEG content in the triblock copolymer films. This result is similar to that of many studies using PEG as a surface modifier [45,46]. It is interesting to note that the water contact angle of PLA/PEG physical blend film with PEG content of 50% (w/w) is 33.5°± 2°; while the PLA-PEG-PLA triblock copolymer films had a relatively high initial water contact angle of 55°± 5°(measured at 10 sec after water-film contact), a) The number after the 'PEG' denotes the PEG content (in percentage) in each copolymer.…”
Section: Hydrophilicity Of the Pla-peg-pla Triblock Copolymerssupporting
confidence: 92%
“…Many studies have reported that hydrophilic surfaces, such as those of hydrogels and PEG-grafted polymers, suppress protein adsorption and platelet adhesion [22,23]. In addition, hydrophilic polymers reduce the hydrophobic interaction between the surface and the proteins, suppressing the conformational changes that induce protein adsorption [24]. In this study, the surfaces of VI-g-PHO copolymers become more hydrophilic with more grafted VI groups.…”
Section: Blood Compatibility Of Vi-g-pho Copolymersmentioning
confidence: 77%
“…Os tempos de ensaio foram de 30 minutos, nas diferentes pressões. O fluxo de água permeada é dado pela Equação 1 [8] :…”
Section: Fluxo De áGua Permeadaunclassified