2011
DOI: 10.1007/s10337-011-2129-9
|View full text |Cite
|
Sign up to set email alerts
|

Preparation of Monolithic Imprinted Stationary Phase for Clenbuterol by In Situ Polymerization and Application in Biological Samples Pretreatment

Abstract: A clenbuterol (CLB) molecule-imprinted monolithic stationary phase (MIMSP) with specific recognition for CLB and some other b 2 -adrenergic receptor agonists was prepared by in situ polymerization technique utilizing methacrylic acid as a functional monomer, ethylene glycol dimethacrylate (EDMA) as a cross-linking reagent, and low polar solvents (toluene and dodecanol) as porogenic solvents. The optimal polymerization conditions were as follows: the molar ratio of template:monomer:initiator was 5:20:1, EDMA wa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 17 publications
(6 citation statements)
references
References 24 publications
0
6
0
Order By: Relevance
“…It was especially notable that the difference of the adsorption capacity ( Q t ) became enlarged with the increase of the RAC concentration within the observed range. The binding isotherms could be estimated by application of the Scatchard analysis model [36] , [37] , i.e. Q/C e =( Q max − Q )/ K d , where Q max is the maximum adsorption capacity, K d is the equilibrium dissociation constant, and C e represents the equilibrium concentration of RAC in solution, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…It was especially notable that the difference of the adsorption capacity ( Q t ) became enlarged with the increase of the RAC concentration within the observed range. The binding isotherms could be estimated by application of the Scatchard analysis model [36] , [37] , i.e. Q/C e =( Q max − Q )/ K d , where Q max is the maximum adsorption capacity, K d is the equilibrium dissociation constant, and C e represents the equilibrium concentration of RAC in solution, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…XRD is used to analyze the diffraction spectroscopy of materials. Generally, a wide-angle XRD pattern indicates the presence of magnetic solids and a low-angle pattern indicates the pore structure of porous magnetic materials [ 94 ]. The XRD results observe the shape of the Fe 3 O 4 diffraction peak and compare this with the standard Fe 3 O 4 diffraction form.…”
Section: Characterization Of Mmipsmentioning
confidence: 99%
“…MIPs offer a number of advantages, in particularly long‐term storage stability, potential re‐usability, resistance to microbial damage, facile integration into transducers , low cost, ease of preparation, and finally, comparable affinity and recognition ability for the target substrate . MIPs have a wide range of applications such as solid phase extraction ,, stationary phases in high performance liquid chromatography ,, capillary electrochomatography drug delivery , and sensors ,.…”
Section: Introductionmentioning
confidence: 99%