2012
DOI: 10.1016/j.aca.2012.05.039
|View full text |Cite
|
Sign up to set email alerts
|

Preparation of methacrylate-based anion-exchange monolithic microbore column for chromatographic separation of DNA fragments and oligonucleotides

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
34
0
3

Year Published

2013
2013
2020
2020

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 41 publications
(38 citation statements)
references
References 50 publications
0
34
0
3
Order By: Relevance
“…The poly-(GMA-co-EDMA) monolith was synthesized by in-situ copolymerization reaction inside a silicon steel tubing (1.02 mm i.d., 1/16 in o.d.) using the procedure described by Sabarudin, et al 18 A mixture of GMA, EDMA, 1-propanol, 1,4-butanediol, water, and AIBN (1% w/v of the total monomer amount) was homogenized using ultrasonication for 10 min and injected into a silanized silicon steel tubing by mean of a-5 mL syringe. Both ends column was sealed, and the polymerization proceeded in the oven at 60°C for 12 h. The resulted monolithic column was then washed with ethanol and water to remove residual reagents.…”
Section: Pretreatment Of Silicosteel Tubing and Preparation Of Ti 4+ mentioning
confidence: 99%
See 1 more Smart Citation
“…The poly-(GMA-co-EDMA) monolith was synthesized by in-situ copolymerization reaction inside a silicon steel tubing (1.02 mm i.d., 1/16 in o.d.) using the procedure described by Sabarudin, et al 18 A mixture of GMA, EDMA, 1-propanol, 1,4-butanediol, water, and AIBN (1% w/v of the total monomer amount) was homogenized using ultrasonication for 10 min and injected into a silanized silicon steel tubing by mean of a-5 mL syringe. Both ends column was sealed, and the polymerization proceeded in the oven at 60°C for 12 h. The resulted monolithic column was then washed with ethanol and water to remove residual reagents.…”
Section: Pretreatment Of Silicosteel Tubing and Preparation Of Ti 4+ mentioning
confidence: 99%
“…Development of microbore column with inner diameter of SEPARATION 0.5 -1.5 mm has been reported. [18][19][20] This kind of column easily utilized to standard HPLC system without any modification. 19,21 In term of applicability, the benefit of microbore column can be used for analysis and also for preparative purposes.…”
Section: Introductionmentioning
confidence: 99%
“…Sebagai media pemisahan, monolith telah banyak diaplikasikan sebagai pengganti kolom partikel konvensional yang selama ini digunakan dalam KCKT. Variasi dan aplikasi kolom monolith telah berkembang dengan pesat dalam dekade terakhir ini dan memainkan peranan yang sangat penting dalam ilmu kimia pemisahan [1,2].…”
unclassified
“…Penggunaan porositas dan ukuran pori yang dapat divariasi, monolith terbukti dapat berfungsi sebagai media pemisahan dalam kromatografi untuk pemisahan berbagai analit, mulai dari molekul berukuran kecil [3,[7][8], hingga makromolekul seperti peptida dan protein [9][10], dan juga oligodeoxythymidylic acids [2].…”
unclassified
“…Microbore column can be easily connected to commercially available standard HPLC system with minor modification. Although requiring more attention to the uneven heating along the diameter of the column during the polymerization process, microbore columns combine the advantages of both capillary and conventional-size columns, that is low sample and reagent consumption, reduced waste, shorten analysis time, and enhanced sensitivity from the small amount of sample [13,28,[30][31][32].…”
Section: Introductionmentioning
confidence: 99%