1983
DOI: 10.1248/cpb.31.1089
|View full text |Cite
|
Sign up to set email alerts
|

Preparation of an ion-selective electrode sensitive to flufenamic acid anion and its application to the study of protein binding of flufenamate in aqueous solution.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0
1

Year Published

1986
1986
2009
2009

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 0 publications
0
3
0
1
Order By: Relevance
“…Similar methods were used to determine the parameters for the binding of bile acids to bovine serum albumin using an ISE for bile acids (14). An ISE for flufenamic acid has also been reported and its response studied in the presence of bovine albumin, but no binding parameters were determined (15). The ISE for dodecyl sulfate and octyl or decyl sulfate were used to study the binding of these ions to bovine albumin (16) and /3-lactoglobulin (17), respectively.…”
Section: Introductionmentioning
confidence: 99%
“…Similar methods were used to determine the parameters for the binding of bile acids to bovine serum albumin using an ISE for bile acids (14). An ISE for flufenamic acid has also been reported and its response studied in the presence of bovine albumin, but no binding parameters were determined (15). The ISE for dodecyl sulfate and octyl or decyl sulfate were used to study the binding of these ions to bovine albumin (16) and /3-lactoglobulin (17), respectively.…”
Section: Introductionmentioning
confidence: 99%
“…1, 2008 To the best of our knowledge, there are a single report on the use of ion-selective potentiometric sensor for the determination of flufenamic acid. 25 However, this electrode has not been applied for the determination of FFA in pharmaceuticals and biological fluids, thus, precluding the assessment of its usefulness in real analysis.…”
Section: Introductionmentioning
confidence: 99%
“…1, 2008 To the best of our knowledge, there are a single report on the use of ion-selective potentiometric sensor for the determination of flufenamic acid. 25 However, this electrode has not been applied for the determination of FFA in pharmaceuticals and biological fluids, thus, precluding the assessment of its usefulness in real analysis.Previous work from this laboratory dealt with the development of mercury(I)-carboxylate electrodes and their application to solution equilibria, [26][27][28][29] food analysis, 30 and pharmaceutical analysis 31,32 involving carboxylate bearing compounds.The aim of the present contribution was to develop a simple and low-cost potentiometric flufenamate ISE immobilized in a graphite matrix (Pt Hg Hg 2 (FF) 2 Graphite, where FF stands for flufenamate ion) and to evaluate the applicability of this sensor to the determination of FFA in dosage forms and human serum samples. …”
mentioning
confidence: 99%
“…τον όρο (D-1) V c -V s με Υ και τον όρο (cV s /F) με Α, τότε η σχέαη (Β 11) γίνεται•. y=:AC s(6)(7)(8)(9)(10)(11)(12) …”
unclassified