2013
DOI: 10.1039/c3ay40180d
|View full text |Cite
|
Sign up to set email alerts
|

Preparation of a dextran sulfate functionalized monolithic silica column for hydrophilic interaction/cation exchange chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 30 publications
0
2
0
Order By: Relevance
“…Small size monolithic silica capillary columns can be prepared and modified in a meter long tube that could provide a high efficiency HILIC column generating 300 000 theoretical plate with a 200 cm column . Monolithic silica capillary columns of good performance can be prepared using information available in the literature and successfully modified while maintaining the column efficiency, as shown in several cited references, for the preparation of reversed-phase, HILIC, affinity, and mixed-mode stationary phases. Successful modification of rod columns was also reported for reversed-phase and chiral stationary phases. ,, Chemical stability and high-temperature stability of the cladding material should be taken into account for rod columns.…”
Section: Monolithic Silica Columnsmentioning
confidence: 99%
“…Small size monolithic silica capillary columns can be prepared and modified in a meter long tube that could provide a high efficiency HILIC column generating 300 000 theoretical plate with a 200 cm column . Monolithic silica capillary columns of good performance can be prepared using information available in the literature and successfully modified while maintaining the column efficiency, as shown in several cited references, for the preparation of reversed-phase, HILIC, affinity, and mixed-mode stationary phases. Successful modification of rod columns was also reported for reversed-phase and chiral stationary phases. ,, Chemical stability and high-temperature stability of the cladding material should be taken into account for rod columns.…”
Section: Monolithic Silica Columnsmentioning
confidence: 99%
“…The optimal H was 10 μm at u = 0.6 mm/s, which was better than the corresponding APTES column. The column showed large retention (k = 20-22) for amino acids in 90% acetonitrile (ACN) (89). Preparation and column efficiency of HILIC monolithic silica columns are summarized in Table 2. 3.2.4.…”
Section: Hydrophilic Interaction Liquid Chromatographymentioning
confidence: 99%
“…In recent years, monolithic columns have become one of the focuses in separation science due to their high permeability, fast mass transfer, absence of end frits, and so on . With different chemical modification, monolithic columns can be applied in various separation modes . So far, mixed‐mode chromatography is more flexible than single‐mode chromatography since it combines the advantages of two or more kinds of separation modes together and reduces the overconsumption of materials and production of wastes .…”
Section: Introductionmentioning
confidence: 99%