2019
DOI: 10.1007/s41230-019-9090-x
|View full text |Cite
|
Sign up to set email alerts
|

Preparation and properties of open-cell zinc foams as human bone substitute material

Abstract: M edical metal materials have good mechanical properties and biocompatibility, and have been widely used as human hard tissue repair and replacement materials [1-3]. However, clinical studies have found that many medical metal materials do not match the elastic modulus of human bones, which will produce "stress shielding" phenomenon when implanted in the human body, resulting in loose or broken implants [4-6]. To solve the above problems, scholars have proposed a method of introducing pores into the medical me… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 27 publications
0
2
0
Order By: Relevance
“…Figure 6 summarises the elastic modulus of porous absorbable metals with respect to their corrosion rates. An ideal bone scaffold should have an elastic modulus which is closer to that of natural bone (0.01-20 GPa) [86]. Referring to the figure, the dynamic immersion apparently led to the diminishing of the elasticity of porous Mg scaffolds and to the acceleration of the corrosion rate despite their lower as-fabricated porosity when compared with and Fe-based counterparts.…”
Section: Corrosion–porosity Relationshipmentioning
confidence: 99%
See 1 more Smart Citation
“…Figure 6 summarises the elastic modulus of porous absorbable metals with respect to their corrosion rates. An ideal bone scaffold should have an elastic modulus which is closer to that of natural bone (0.01-20 GPa) [86]. Referring to the figure, the dynamic immersion apparently led to the diminishing of the elasticity of porous Mg scaffolds and to the acceleration of the corrosion rate despite their lower as-fabricated porosity when compared with and Fe-based counterparts.…”
Section: Corrosion–porosity Relationshipmentioning
confidence: 99%
“…The production of porous Fe-based scaffolds in a higher porosity (>80%) considerably deteriorates its elastic modulus to 0.003-0.2 GPa, even though the porosity is in the range of cancellous bone's porosity (40-90%) [86]. Higher porosity can facilitate tissue growth but at the expense of losing elasticity.…”
Section: Corrosion–porosity Relationshipmentioning
confidence: 99%