2020
DOI: 10.1016/j.jelechem.2020.114653
|View full text |Cite
|
Sign up to set email alerts
|

Preparation and characterization of reusable Sonogel-Carbon electrodes containing carbon black: Application as amperometric sensors for determination of cathecol

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 33 publications
1
4
0
Order By: Relevance
“…It is evident that the presence of CB induces electrocatalytic effects, leading to much higher current values recorded during the oxidation of CA than those recorded with unmodified SNGC electrodes. Similar effects were also observed in our previous work concerning catechol and hydroquinone [ 21 ]. The linear regression equation related to the variation of the anodic peak current with CA concentration when using SNGC-CB electrodes was as follows: I (A) = (3.95 ± 0.11) × 10 −3 [CA] + (4.8 ± 1.9) × 10 −9 with a correlation coefficient of R 2 = 0.995 3 (S y/x = 3.45 × 10 −9 , 26 points overall, 95% confidence level).…”
Section: Resultssupporting
confidence: 90%
See 3 more Smart Citations
“…It is evident that the presence of CB induces electrocatalytic effects, leading to much higher current values recorded during the oxidation of CA than those recorded with unmodified SNGC electrodes. Similar effects were also observed in our previous work concerning catechol and hydroquinone [ 21 ]. The linear regression equation related to the variation of the anodic peak current with CA concentration when using SNGC-CB electrodes was as follows: I (A) = (3.95 ± 0.11) × 10 −3 [CA] + (4.8 ± 1.9) × 10 −9 with a correlation coefficient of R 2 = 0.995 3 (S y/x = 3.45 × 10 −9 , 26 points overall, 95% confidence level).…”
Section: Resultssupporting
confidence: 90%
“…SNGC-CB electrodes were prepared according to the procedure described in ref. [ 21 ]. Briefly, a mixture of 300 mg of graphite /150 mg of CB was added to a sonosol obtained after sonicating 0.5 mL methyltrimethoxysilane and 0.1 mL of 0.2 M HCl for 5 s. The resulting material was then inserted and compacted inside a glass capillary tube, i.d.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, an electrochemical cleaning process of 6 cycles (50 mV/s) with CV in KOH solution was necessary after each measurement [34]. Similar harsh conditions were used for cleaning step in the analysis of PCMC with the SNG-C-PANI sensor device, with 15 sweeps using CV [3].…”
Section: Analytical Calibration Of Different Chlorophenolsmentioning
confidence: 99%