2014
DOI: 10.1016/j.jcrs.2013.11.047
|View full text |Cite
|
Sign up to set email alerts
|

Preloaded refractive-addition corneal inlay to compensate for presbyopia implanted using a femtosecond laser: One-year visual outcomes and safety

Abstract: No author has a financial or proprietary interest in any material or method mentioned.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(23 citation statements)
references
References 13 publications
0
21
0
2
Order By: Relevance
“…Thermal alteration of corneal collagen occurs when the tissue is exposed to temperatures of 58°to 75°C. In detail, the collagen matrix changes from the triple helix formation to a partially coiled structure resulting in shrinkage of collagen fibers [10][11][12][13][14]. Opti-K, with the use of sapphire applanation ring, confines thermal elevation into the anterior corneal stroma, which produces limited thermally damaged zones that compact the anterior stromal lamellae while preserving the overlying epithelium.…”
Section: Discussionmentioning
confidence: 99%
“…Thermal alteration of corneal collagen occurs when the tissue is exposed to temperatures of 58°to 75°C. In detail, the collagen matrix changes from the triple helix formation to a partially coiled structure resulting in shrinkage of collagen fibers [10][11][12][13][14]. Opti-K, with the use of sapphire applanation ring, confines thermal elevation into the anterior corneal stroma, which produces limited thermally damaged zones that compact the anterior stromal lamellae while preserving the overlying epithelium.…”
Section: Discussionmentioning
confidence: 99%
“…[18][19][20] With other commercially available inlays, a more significant loss of 2 to 3 lines of UDVA has been reported. [21][22][23] Loss of 1 line of BDVA has been reported between 2.6% and 28.3% with the Kamra inlay. 18,19,20,24 Other authors have reported loss of 1 line of BDVA in 37% to 77% of eyes implanted with other commercially available inlays.…”
Section: ' Postoperative Complicationsmentioning
confidence: 99%
“…18,19,20,24 Other authors have reported loss of 1 line of BDVA in 37% to 77% of eyes implanted with other commercially available inlays. 22,25 Subjective visual complaints such as glare, halos, and night vision problems can occur after inlay implantation, but are mostly mild to moderate in severity and similar to the visual symptoms after LASIK. 19,26 The explantation rate in cases of visual dissatisfaction varies widely across series from 0% to 21%.…”
Section: ' Postoperative Complicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…23 The Raindrop Near Vision Inlay (ReVision Optics, Lake Forest, California, USA) is a CI that changes the corneal curvature. Garza et al 21 reported good and stable results at 1 year.…”
Section: Pseudoaccommodative Approachesmentioning
confidence: 99%