Preliminary comparison of inductively coupled plasma mass spectrometry and electrospray mass spectrometry hyphenated with ion chromatography for trace analysis of iodide

Abstract: Ion-exchange chromatography hyphenated with mass spectrometric detection has been investigated for the determination of iodide in urine. Satisfactory chromatographic behavior of iodide could be achieved on a hydrophilic polymer-based anion-exchange column with 35 mM sodium hydroxide as the mobile phase. When electrospray ionization (ESI) was used, a suppressor as well as a flow splitter (split ratio 1 : 10) was required between the column and the interface. In the case of an inductively coupled plasma (ICP) io… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2004
2004
2018
2018

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 14 publications
(14 reference statements)
0
9
0
Order By: Relevance
“…29 Mass spectrometry can also be used as a detector in conjunction with liquid or ion chromatography to provide information on iodine species. 31,32 As with all trace element analysis, measurement of iodine is prone to contamination from a variety of sources including urine dipsticks as was recently reported. 33 Urine iodine in populations UI concentration has long been used as the standard means with which to assess the iodine status within a given population.…”
Section: Urine Iodinementioning
confidence: 96%
“…29 Mass spectrometry can also be used as a detector in conjunction with liquid or ion chromatography to provide information on iodine species. 31,32 As with all trace element analysis, measurement of iodine is prone to contamination from a variety of sources including urine dipsticks as was recently reported. 33 Urine iodine in populations UI concentration has long been used as the standard means with which to assess the iodine status within a given population.…”
Section: Urine Iodinementioning
confidence: 96%
“…In a set of seawater samples concentrations of 25.5-29.3 g L −1 for iodate and 27.7-31.6 g L −1 for iodide were determined, respectively. Buchberger and co-workers described the development of an analytical method combining anion-exchange chromatography on a hydrophilic polymer-based stationary phase using 35 mM aqueous NaOH as eluent with either ESI-MS (single quadrupole), ICP-QMS or ICP-SFMS for speciation of iodide in matrix-rich samples [83]. Significantly lower detection limits were obtained with ICP-SFMS (0.01 g L −1 ) and ICP-QMS (0.1 g L −1 ) in comparison with ESI-MS (15 g L −1 ).…”
Section: Iodine and Brominementioning
confidence: 99%
“…The most common of the traditional methods is colorimetry based on the Sandell-Kolthoff reaction, in which iodide catalyzes the reduction of ceric ammonium sulfate by arsenious acid (15)(16)(17)(18). The emergence of newer instrumental methods based on coupled ion chromatography and inductively coupled plasma mass spectrometry (ICP-MS) permit measurements of greater specificity and sensitivity, although at higher cost (19)(20)(21)(22).…”
Section: Srms For Urinary Iodinementioning
confidence: 99%