2019
DOI: 10.1080/14767058.2019.1670798
|View full text |Cite
|
Sign up to set email alerts
|

Prediction of time of delivery using cervical length measurement in women with threatened preterm labor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 13 publications
0
8
0
Order By: Relevance
“…However, no significant link has been found between cervix funnelling and preterm labor before week 37. 10,21,31 In our study, we used fundal pressure as a method to induce dynamic cervical changes. A large-scale study in Japan found that uterine fundal pressure maneuvers (UFPM) is used in 11.4% of total vaginal deliveries in 89.4% of perinatal medical centers Japan association of obstetricians and gynecologists, 2014.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, no significant link has been found between cervix funnelling and preterm labor before week 37. 10,21,31 In our study, we used fundal pressure as a method to induce dynamic cervical changes. A large-scale study in Japan found that uterine fundal pressure maneuvers (UFPM) is used in 11.4% of total vaginal deliveries in 89.4% of perinatal medical centers Japan association of obstetricians and gynecologists, 2014.…”
Section: Discussionmentioning
confidence: 99%
“…9 Cervical ultrasounds should be utilized instead of manual evaluations, according to the findings of several research. 10,18 In both asymptomatic high-risk and low-risk women, it has been demonstrated that the evaluation of CL by ultrasonography (USG) is superior to digital examination as a predictor of preterm delivery. 11 Trans vaginal ultrasound (TVUS) is the industry leader in CL evaluation.…”
Section: Introductionmentioning
confidence: 99%
“…Similar to our study, studies in the literature using various combinations of serum or vaginal biomarkers with CL measurement for prediction of preterm delivery in threatened preterm labor also performed serum biomarker measurements as early as possible at the time of diagnosis of threatened preterm birth. 48 Cervical length measurement by transvaginal sonography during evaluation for preterm labor symptoms was measured with a 4 to 10 MHz transvaginal probe (Toshiba Medical Systems Corporation, Japan) with an empty bladder. Research personnel performing transvaginal CL measurement were trained, and all images were reviewed for adequacy and accuracy using the protocol described by Iams et al at the time of image ascertainment.…”
Section: Methodsmentioning
confidence: 99%
“…Several observational studies have analyzed the performance of TVS CL measurement in the prediction of PTB in symptomatic singleton pregnancy [132][133][134] . One study, encompassing more than 1000 singleton pregnancies with threatened PTL and cervical dilation < 3 cm, reported that TVS CL measurement was associated independently with the risk of PTB in both patients with closed and those with dilated cervix 133 .…”
Section: Ultrasound In the Management Of Singleton Pregnancy With Sym...mentioning
confidence: 99%