2017
DOI: 10.1016/j.microc.2016.10.025
|View full text |Cite
|
Sign up to set email alerts
|

Preconcentration and speciation of thallium by ferrofluid based dispersive solid phase extraction and flame atomic absorption spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(17 citation statements)
references
References 39 publications
0
17
0
Order By: Relevance
“…Practically, no extraction for the metals investigated was observed for pH values between 1-3. Low pH values make the surface of the nanoparticle positive, leading to low metal retention [25][26][27]. The analytical signals for all metals increase significantly from pH 5 and highest extractions were obtained in the pH range of 5-7.…”
Section: Resultsmentioning
confidence: 99%
“…Practically, no extraction for the metals investigated was observed for pH values between 1-3. Low pH values make the surface of the nanoparticle positive, leading to low metal retention [25][26][27]. The analytical signals for all metals increase significantly from pH 5 and highest extractions were obtained in the pH range of 5-7.…”
Section: Resultsmentioning
confidence: 99%
“…new alternatives for their treatment [5,6]. There are several methods available to detect trace metal ions such as chemical precipitation/coprecipitation [7], liquid-liquid extraction [8], and solid phase extraction (SPE) [9]. SPE has been considered as the most efficient technique compared with the others for its simplicity, economics, rapidity, and consumption of small volume of reagents.…”
Section: Nano-chamomile Waste As a Low-cost Biosorbent For Rapid Remomentioning
confidence: 99%
“…The kinetics of metals adsorption on NCW is also described as pseudo-second order Eq. (7) [48]: t/q t = 1/k 2 q e 2 + 1/q e t (7) where k 2 (gmmoL -1 min -1 ) is the constant of pseudo-second-order rate. The value of q e and k 2 are experimentally determined from the slope and the intercept of the plot t/q t versus t. As shown in Fig.…”
Section: Kinetic Studiesmentioning
confidence: 99%
“…The main preparation procedure of FFs is quite simple: the direct mixing of the precursors (stabilized MNPs and carrier, or MNPs, stabilizer, and carrier) for a certain time, to ensure the formation of a quite homogeneous colloidal suspension. Ultrasonic energy is the most common assistance method used to ensure such uniform and energic mixing [5,9,[13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28]. In any case, the preparation of any FF clearly requires the synthesis of the MNPs, and, in several cases, the surface modification of the MNPs, and/or the synthesis of the carrier solvent if it is not commercially available.…”
Section: Introductionmentioning
confidence: 99%