1977
DOI: 10.1021/ac50012a017
|View full text |Cite
|
Sign up to set email alerts
|

Precision of flame atomic absorption measurements of arsenic, cadmium, calcium, copper, iron, magnesium, molybdenum, sodium, and zinc

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
29
0

Year Published

1978
1978
2003
2003

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 42 publications
(32 citation statements)
references
References 6 publications
(9 reference statements)
3
29
0
Order By: Relevance
“…Since more than three decades ago, there have been published many theories and methods for estimating SD with no recourse to repetition, especially in instrumental analyses. [12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27] In spite of varied symbols and terminology in the literature, the largest part of uncertainty equations proposed can take a universal form:…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Since more than three decades ago, there have been published many theories and methods for estimating SD with no recourse to repetition, especially in instrumental analyses. [12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27] In spite of varied symbols and terminology in the literature, the largest part of uncertainty equations proposed can take a universal form:…”
Section: Introductionmentioning
confidence: 99%
“…Examples are LOD, 21,24,26,28 confidence intervals of linear calibration 28 and tests of significant differences. 3,4,6 Theoretical SD descriptions elaborated so far include Winefordner's theory, [18][19][20] Ingle's theory, [15][16][17] Bouman's theory 21,22 and FUMI theory (FUnction of Mutual Information). [23][24][25] Proceeding along the lines suggested by the FUMI theory, our approach is named after it.…”
Section: Introductionmentioning
confidence: 99%
“…Btlx 1663, Los Alamos, N.M. 87544. decades, relatively good powers of detection. and minimal matrix effects provided the impetus to consider exploding-foil excitation For micro solution samples (3,4).…”
Section: Discussionmentioning
confidence: 99%
“…The different noises measured are identified below in accordance with the terminology developed by Ingle and Bower (3,4 ) . dot is the standard deviation in the signal recorded with the HC lamp and flame off and is due to amplifier-readout noise and dark current noise from the PMT.…”
Section: (3 4 )mentioning
confidence: 99%
“…These measurements are a compilation of information from several sources, but primarily from the work of Ingle [20,21] Finally, zinc is an example of an element whose absorption wavelength is lower than 230 nm, the range where flame transmission noise dominates.…”
Section: Absorption Noise Sourcesmentioning
confidence: 99%