“…20 When using two lag screws besides anatomical fracture reduction, insertion of the inferior lag screw as close as possible to inferior cortex of the femoral neck is strongly recommended as the tensile and compressive trabecula of the proximal femur intersect at that area so making this place for the strongest screw purchase, but unfortunately it may not be always possible to place inferior lag screw in proper place due to anatomical and surgeon experience. 7,20 Also in patients with small femoral neck diameter it may sometimes be very hard to find enough space for two screw insertion.…”
Section: Resultsmentioning
confidence: 99%
“…20 When using two lag screws besides anatomical fracture reduction, insertion of the inferior lag screw as close as possible to inferior cortex of the femoral neck is strongly recommended as the tensile and compressive trabecula of the proximal femur intersect at that area so making this place for the strongest screw purchase, but unfortunately it may not be always possible to place inferior lag screw in proper place due to anatomical and surgeon experience. 7,20 Also in patients with small femoral neck diameter it may sometimes be very hard to find enough space for two screw insertion.…”
Section: Resultsmentioning
confidence: 99%
“…In proximal femoral fractures, optimal placement of the guide wire for the lag screw is mandatory to achieve good results [ 1 , 2 ]. Often, multiple trials are needed to introduce it correctly [ 4 ]. It seems safe to assume that multiple drill holes around the final screw or blade of an implant may weaken the bone and lead to the more common screw cutout than when the bone around the implant is intact.…”
Section: Discussionmentioning
confidence: 99%
“…In proximal femoral fractures, optimal placement of the guide wire for the lag screw is mandatory to achieve good results [1,2]. Often, multiple trials are needed to introduce it correctly [4]. It seems safe to assume that multiple drill holes around…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Poyanli y cols. 12 presentan un método para poder mejorar y simplificar la imagen del fémur proximal en el perfil, compensando la anteversión del fémur y, por lo tanto, dejando una imagen que es paralela al piso y que contribuiría a evaluar, con más facilidad, la reducción y la colocación del implante.…”
Section: Adecuada Visualizaciónunclassified