1990
DOI: 10.1016/0165-9936(90)87045-n
|View full text |Cite
|
Sign up to set email alerts
|

Practical options for microwave digestions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
1

Year Published

1992
1992
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(5 citation statements)
references
References 11 publications
0
4
0
1
Order By: Relevance
“…For acid digestion, a sample (ca. 0.1 dry weight) was transferred into a Teflon 1 PFA vessel covered with a double-sealed Teflon decomposition vessel (type-P-70, SAN-AI science Co. Ltd., Nagoya, Japan) with 4 ml nitric acid and heated for 3 min with a microwave (Kimber and Kokot 1990). Digested samples were then diluted to 20 ml with ultra-pure water.…”
Section: Measurements Of the Sodium And Copper Concentrationsmentioning
confidence: 99%
“…For acid digestion, a sample (ca. 0.1 dry weight) was transferred into a Teflon 1 PFA vessel covered with a double-sealed Teflon decomposition vessel (type-P-70, SAN-AI science Co. Ltd., Nagoya, Japan) with 4 ml nitric acid and heated for 3 min with a microwave (Kimber and Kokot 1990). Digested samples were then diluted to 20 ml with ultra-pure water.…”
Section: Measurements Of the Sodium And Copper Concentrationsmentioning
confidence: 99%
“…The mineralization temperature should be controlled to avoid excessive heating of the reactors. PTFE vessels are not recommended for use above 200 °C (Kimber and Kokot, 1990). Experiments were made to assess the pressure and temperature generated during digestion in the conditions described above (Figure 1).…”
Section: Resultsmentioning
confidence: 99%
“…This material was chosen because it has a softening point of about 250 °C and shows low surface adsorption of ions. To avoid the leaching of contaminating substances, we have adopted the cleanup procedure recommended by Kimber and Kokot (1990) for trace analysis: The reactors were heated at 448 W in the microwave for 10 min with 50% HNO3 and then thoroughly rinsed with deionized water. Moreover, all reactors, glassware, and crucibles were kept in 10% HNO3 and were rinsed thoroughly with distilled water before use.…”
Section: Methodsmentioning
confidence: 99%
“…Polytetrafluoroethylene, PTFE) are the material of choice thanks to their stability, chemical inertia and transparency to MW radiation. 6 However, sample contamination may occur because of infiltration and trapping of gases or other phases into the polymer during the digestion treatment. 7,8 The employment of highly pure quartz may be a simple strategy to overcome this problem.…”
Section: Introductionmentioning
confidence: 99%