2007
DOI: 10.1111/j.1610-0387.2007.06245.x
|View full text |Cite
|
Sign up to set email alerts
|

PPL and MDM skin test: New test kit is helpful in detecting immediate‐type allergy to beta‐lactams

Abstract: Our data show that the new test kit may be helpful in detecting patients with immediate type allergy to beta-lactams. Without this test, in those three patients reacting exclusively to MDM, and oral provocation test would have been necessary to clarify their allergy. Data from larger groups of patients are needed to determine the sensitivity and specificity of this test kit.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2007
2007
2018
2018

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…Van Dellen and Gleich, 1970 25 Sullivan et al, 1981 26 Romano et al, 1995 27 Romano et al, 1997 28 31 Sogn et al, 1992 32 PPL+ benzylpenicillin + benzylpenicilloate + benzylpenilloate Adkinson, Jr., et al, 1971 33 Chandra et al, 1980 34 Mendelson et al, 1984 35 Gadde et al, 1993 36 Pichichero and Pichichero, 1998 37 Klaustermeyer and Gowda, 2005 38 Treudler et al, 2007 39 Frigas et al, 2008 40 Nolan et al, 2008 41 Raja et al, 2009 42 PPL + benzylpenicillin + benzylpenicilloate + benzylpenilloate + amoxicillin Macy et al, 1997 43 Macy et al, 2010 44 Lin et al, 2010 45 Kopac et al, 2012 46 Geng et al, 2017 47 Marwood et al, 2017 48 51 Matheu et al, 2007 52 Romano et al, 2007 53 Romano et al, 2009 54 Romano et al, 2010 55 Richter et al, 2011 56 Al-Ahmad et al, 2014 57 Bourke et al, 2015 58 Abbreviations: MDM, minor determinant mixture; PPL, penicilloyl-polylysine.…”
Section: Ppl+ Benzylpenicillin + Benzylpenicilloate + Ampicillin + Other Reagentsmentioning
confidence: 99%
See 1 more Smart Citation
“…Van Dellen and Gleich, 1970 25 Sullivan et al, 1981 26 Romano et al, 1995 27 Romano et al, 1997 28 31 Sogn et al, 1992 32 PPL+ benzylpenicillin + benzylpenicilloate + benzylpenilloate Adkinson, Jr., et al, 1971 33 Chandra et al, 1980 34 Mendelson et al, 1984 35 Gadde et al, 1993 36 Pichichero and Pichichero, 1998 37 Klaustermeyer and Gowda, 2005 38 Treudler et al, 2007 39 Frigas et al, 2008 40 Nolan et al, 2008 41 Raja et al, 2009 42 PPL + benzylpenicillin + benzylpenicilloate + benzylpenilloate + amoxicillin Macy et al, 1997 43 Macy et al, 2010 44 Lin et al, 2010 45 Kopac et al, 2012 46 Geng et al, 2017 47 Marwood et al, 2017 48 51 Matheu et al, 2007 52 Romano et al, 2007 53 Romano et al, 2009 54 Romano et al, 2010 55 Richter et al, 2011 56 Al-Ahmad et al, 2014 57 Bourke et al, 2015 58 Abbreviations: MDM, minor determinant mixture; PPL, penicilloyl-polylysine.…”
Section: Ppl+ Benzylpenicillin + Benzylpenicilloate + Ampicillin + Other Reagentsmentioning
confidence: 99%
“…70,71 The safety of penicillin skin testing was assessed in a review of 54 studies published over a period of 49 years. [13][14][15][16][17][18][19][20][21][22][24][25][26]30,[32][33][34][36][37][38][39][41][42][43][44][45][46][47][48][49][50][52][53][54][55][56][57][58][72][73][74][75][76][77][78][79][80][81][82][83][84]...…”
Section: Sensitivity and Safety Of Penicillin Skin Test Evaluations In History-positive Patientsmentioning
confidence: 99%
“…This new kit contains PPL, yet the MDM now only comprises benzylpenicilloate, eliminating benzylpenicillin and benzyl penicilloic acid from the classical evaluation [5]. Although some concern remains that the elimination of this compounds will lead to a reduction of sensitivity in the skin test evaluation, multiple studies carried so far have reveal that these two formulations are equivalent [21][22][23].…”
Section: Immediate Hypersensitivitymentioning
confidence: 99%