2021
DOI: 10.1007/s42835-020-00644-x
|View full text |Cite
|
Sign up to set email alerts
|

Power Quality Enhancement in Grid-Connected PV/Wind/Battery Using UPQC: Atom Search Optimization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 52 publications
(23 citation statements)
references
References 27 publications
0
10
0
Order By: Relevance
“…The characteristics of both filters are designed in providing the best performance under various operating conditions. To filter out the harmonics, the designed structure is modeled with storage systems using the battery, DC link, and switches with antiparallel diodes (Goud and Rao, 2021). At PCC, compensating current is injected using a voltage source converter to mitigate the harmonics.…”
Section: Proposed Test Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…The characteristics of both filters are designed in providing the best performance under various operating conditions. To filter out the harmonics, the designed structure is modeled with storage systems using the battery, DC link, and switches with antiparallel diodes (Goud and Rao, 2021). At PCC, compensating current is injected using a voltage source converter to mitigate the harmonics.…”
Section: Proposed Test Systemmentioning
confidence: 99%
“…r 1 and r 2 indicate the random vector, which varies between (0, 1), while the component "a" falls from 2 to 0 throughout the iteration. Using the below equations (Durairasan and Balasubramanian, 2020;Kuchibhatla et al, 2020;Goud and Rao, 2021), the hunting process is calculated…”
Section: Gray Wolf Optimization Techniquementioning
confidence: 99%
“…Where Il, Il are phase neutral currents and I La , I Lb , I Lc are three-phase load currents, respectively. V Sa , V Sb , and V Sc are three-phase supply voltages, whereas V Sα , V Sβ , are phaseneutral voltages [25][26][27][28][29][30]. The real and unconsidered powers of instantaneous values are calculated using phase neutral voltages and load currents.…”
Section: Control Structure Of Shunt Active Power Filtermentioning
confidence: 99%
“…Specifically, the associated power quality issues of the distribution systems include power factor degradation, harmonic current introduction, interruption, instantaneous voltage drop (Sag), instantaneous voltage rise (Swell), and voltage unbalance. FACTS facilities have recently been researched to compensate for these power quality issues [5], [6]. In particular, a D-STATCOM is a compensating device that is used to control reactive power flows in the distribution systems and enhance voltage stability [7].…”
Section: Introductionmentioning
confidence: 99%