1996
DOI: 10.1016/0003-2670(95)00515-3
|View full text |Cite
|
Sign up to set email alerts
|

Potentiometric membrane sensors for the selective determination of cinnarizine in pharmaceutical preparations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
8
0

Year Published

1998
1998
2016
2016

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 12 publications
0
8
0
Order By: Relevance
“…The separate solution method 18,19) with aˆxed concentration of the interferent (10 -3 M) was used for evaluation of the selectivity. The results obtained by the developed sensors, Table 2, showed reasonable selectivity for the two sensors for tiapride hydrochloride in presence of any of the mentioned interferent.…”
Section: Resultsmentioning
confidence: 99%
“…The separate solution method 18,19) with aˆxed concentration of the interferent (10 -3 M) was used for evaluation of the selectivity. The results obtained by the developed sensors, Table 2, showed reasonable selectivity for the two sensors for tiapride hydrochloride in presence of any of the mentioned interferent.…”
Section: Resultsmentioning
confidence: 99%
“…[8][9][10] It has been used in the formation of many sensors. [11][12][13] In this work, it has been found that RIV reacts with (TpClPB) to form water insoluble ion association complexes. The high lipophilicity and remarkable stability of these complexes suggested their selective use as electroactive materials in PVC matrix membrane sensors for the determination of the drug studied, in the presence of its degradation product and related substances.…”
mentioning
confidence: 89%
“…Alternatively, several methods have been described in the literature for the determination of CNZ in its pharmaceutical dosage forms or in biological samples. Examples of these methods are various spectrophotometric and/or chemometric spectrophotometric methods (El-Gindy et al, 2004;Metwally et al, 2005;Gazy et al, 2006;El-Bardicy et al, 2008;Abdelrahman, 2013), synchronous fluorescence spectroscopy , chemiluminescence using flow-injection analysis (Townshend et al, 2003), voltammetry Hegde et al, 2009), potentiometric membrane sensors (Hassan et al, 1996), HPLC with UV detection (El-Gindy et al, 2004;Metwally et al, 2005;Heda et al, 2010;Navaneethan et al, 2013), HPLC with fluorescence detection (Angelov and Christova-Bagdassarian, 2003;Nowacka-Krukowska et al, 2007) and capillary electrophoresis . Few articles reported the HPTLC determination of pharmaceutical mixtures containing CNZ with piracetam (Metwally et al, 2005) and domperidone (Argekar and Powar, 1999;Bagade et al, 2005;Vinodhini et al, 2005).…”
Section: Introductionmentioning
confidence: 99%