2010
DOI: 10.1016/j.joen.2010.02.010
|View full text |Cite
|
Sign up to set email alerts
|

Potential Relationship between Design of Nickel-Titanium Rotary Instruments and Vertical Root Fracture

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

6
172
1
7

Year Published

2014
2014
2017
2017

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 184 publications
(186 citation statements)
references
References 39 publications
(41 reference statements)
6
172
1
7
Order By: Relevance
“…However, the micro-CT technology provides the possibility to examine the dentinal tissue before the root canal preparation, which is indeed a very suitable and important feature. The absence of new dentinal defects found after canal preparation with PTU system in the current study markedly contrasts with the results of previous studies, which showed that rotary canal preparation with this system could initiate and/or propagate dentinal micro-cracks (3,4,6,8,9,22). Bier and colleagues (4) observed cracks in 16% of horizontal sections of the roots instrumented with PTU system.…”
Section: Dentinal Defects and Root Canal Preparationcontrasting
confidence: 99%
See 1 more Smart Citation
“…However, the micro-CT technology provides the possibility to examine the dentinal tissue before the root canal preparation, which is indeed a very suitable and important feature. The absence of new dentinal defects found after canal preparation with PTU system in the current study markedly contrasts with the results of previous studies, which showed that rotary canal preparation with this system could initiate and/or propagate dentinal micro-cracks (3,4,6,8,9,22). Bier and colleagues (4) observed cracks in 16% of horizontal sections of the roots instrumented with PTU system.…”
Section: Dentinal Defects and Root Canal Preparationcontrasting
confidence: 99%
“…Bier and colleagues (4) observed cracks in 16% of horizontal sections of the roots instrumented with PTU system. Kim and coauthors (3) reported that the same system generated extreme tensile and compressive stresses in root dentin compared to the ProFile (Dentsply Maillefer) constant tapered rotary system. The authors also speculated that higher root stress concentrations would result in thinner dentinal areas and, consequently, the increasing risk of creating defects.…”
Section: Dentinal Defects and Root Canal Preparationmentioning
confidence: 99%
“…43 Farklı döner sistemlerin vertikal kök kırıkları üzerine etkilerinin incelendiği bir çalışmada, ProTaper eğelerinin kök dentin yüzeyinde daha fazla strese yol açtığı ve daha yüksek derecede gerilimlere neden olduğu ortaya konmuştur. 44 Kök kanal preparasyon sistemlerinin mikro çatlak oluşturma üzerine etkisinin incelendiği bir başka çalışmada, ProTaper sisteminin daha yüksek oranda dentin çatlağına neden olduğu belirtilmiştir. 45 Çalışmamızda elde ettiğimiz sonuç bahsedilen çalışma sonuçları ile uyumludur.…”
Section: 27unclassified
“…It is as yet unclear whether craze lines and incomplete cracks may propagate into complete cracks and fractures after completion of the root canal treatment. In addition, following treatment procedures such as post-space preparation or retreatment are discussed as cofactors for the development of dentinal defects or fractures [1,[23][24][25].…”
Section: Brazilian Research Inmentioning
confidence: 99%