Postal dosimetry audit test for small photon beams

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 30 publications
0
7
0
Order By: Relevance
“…IC = ionisation chamber; DD = dose difference. Reference Audited systems Treatment technique Dosimeter Phantom Dosimetric/Gamma Criteria Results/success rate Clark et al [26] 43 VMAT, Tomotherapy Planar array Commercial phantom >95% for 3%/3 mm global gamma Test plan: 79,1% Clinical plan: 97,6% Schiefer et al [48] 20 Tomotherapy TLD, IC Cylindrical Perspex phantom <5% DD <3% DD 100% 93,3% Lafond et al [23] 13 IMRT, VMAT IC, film Commercial phantom >95% for 5%/3 mm 3%3 mm Local gamma IC dose within 3% Sag/cor plane 100%/100% 80%/93% Palmer et al [39] 12 Conformal, IMRT, VMAT film Respiratory motion lung-phantom 3%2 mm Global gamma Static phantom: 98,7% Moving-phantom: 88,2% Miri et al [79] 6 IMRT, VMAT Portal dosimetry none 3%/3 mm 3%,/2 mm 2%/2 mm 3 Varian/3 Elekta 99.5%/99.7% 98.9%/97.8% 95.9%/95.3% Nakamura et al [40] 44 IMRT, VMAT, Tomotherapy IC, film In-house developed phantom IC: <3% DD Film:<2 mm positional difference 100% 100% (1,0 ± 0,4 mm) Espinosa et al [45] 14 IMRT, SRS TLD Cylindrical PMMA phantom <5% DD 1 × 1 cm 2 : 69% 3 × 3 cm 2 : 64% Izewska et al …”
Section: Phantom Based Methods For Dosimetry Auditsmentioning
confidence: 99%
See 1 more Smart Citation
“…IC = ionisation chamber; DD = dose difference. Reference Audited systems Treatment technique Dosimeter Phantom Dosimetric/Gamma Criteria Results/success rate Clark et al [26] 43 VMAT, Tomotherapy Planar array Commercial phantom >95% for 3%/3 mm global gamma Test plan: 79,1% Clinical plan: 97,6% Schiefer et al [48] 20 Tomotherapy TLD, IC Cylindrical Perspex phantom <5% DD <3% DD 100% 93,3% Lafond et al [23] 13 IMRT, VMAT IC, film Commercial phantom >95% for 5%/3 mm 3%3 mm Local gamma IC dose within 3% Sag/cor plane 100%/100% 80%/93% Palmer et al [39] 12 Conformal, IMRT, VMAT film Respiratory motion lung-phantom 3%2 mm Global gamma Static phantom: 98,7% Moving-phantom: 88,2% Miri et al [79] 6 IMRT, VMAT Portal dosimetry none 3%/3 mm 3%,/2 mm 2%/2 mm 3 Varian/3 Elekta 99.5%/99.7% 98.9%/97.8% 95.9%/95.3% Nakamura et al [40] 44 IMRT, VMAT, Tomotherapy IC, film In-house developed phantom IC: <3% DD Film:<2 mm positional difference 100% 100% (1,0 ± 0,4 mm) Espinosa et al [45] 14 IMRT, SRS TLD Cylindrical PMMA phantom <5% DD 1 × 1 cm 2 : 69% 3 × 3 cm 2 : 64% Izewska et al …”
Section: Phantom Based Methods For Dosimetry Auditsmentioning
confidence: 99%
“…The phantom and the audit methodology have been tested in multi-centre studies and found to be adequate and feasible for meeting the audit objectives. Other dosimetry audit approaches have focused on verifying the beam output for small fields [45] , see Table 2 .…”
Section: Phantom Based Methods For Dosimetry Auditsmentioning
confidence: 99%
“… Small field dosimetric measurements should be verified independently, either through measurements or through an independent external audit, such as that carried out by IROC‐Houston 325,326 or in European countries with postal dosimetry services as described by del Mar Espinosa et al 327 referring to published data would also be helpful. A phantom test from CT simulation through treatment delivery, known as an end‐to‐end test, should be performed and may involve an independent assessment of the delivered dose (Section 6.6). …”
Section: Key Recommendations and Summarymentioning
confidence: 99%
“…The accuracy is probably limited to 5% (117,118). The use of ionisation chambers is not recommended due to poor positioning possibilities.…”
Section: Point Dose Verification Near Organsmentioning
confidence: 99%