1978
DOI: 10.1139/p78-194
|View full text |Cite
|
Sign up to set email alerts
|

Positron annihilation in the alkali halides

Abstract: Position lifetime spectra and Doppler broadening spectra have been measured for 17 alkali halides. Three significant lifetime components are found in almost all cases. The results are interpreted in terms of a model in which a fraction of the positrons form positronium and the remainder are initially in a state from which either annihilation or transitions may occur. The annihilation rate from the initial state is shown to depend on the distance separating negative ions, which suggests that the positron is in … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1980
1980
1995
1995

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…On the contrary, z, decreases from 400 to 255ps, although not linearly. The behavior of z1 in ionic crystals is an important feature of these solids: The lifetime increase with the crystal density [13]. The sulphates studied in this work are listed in Table 1 in the order of increasing density.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…On the contrary, z, decreases from 400 to 255ps, although not linearly. The behavior of z1 in ionic crystals is an important feature of these solids: The lifetime increase with the crystal density [13]. The sulphates studied in this work are listed in Table 1 in the order of increasing density.…”
Section: Discussionmentioning
confidence: 99%
“…The possibility of the annihilation of these positrons from a bound state [13] has also been considered, but it has never been given a clear picture of the details, although that state should be associated to a shallow trap.…”
Section: Discussionmentioning
confidence: 99%
“…The time spectrum of unirradiated samples has been fitted with two exponential decay components; the values obtained agree with those reported for this material by Linderoth et a1 (1986). A three-terms fit, as suggested by other authors (Kerr et al 1978) yields a very low value for 23 (less than 1%) and does not substantially improve the variance of the fit. However, for irradiated samples a third component (q = 1000 ps, Z3 = 6%) has been necessary in order to fit the data.…”
Section: Resultsmentioning
confidence: 69%