Abstract: Detecting the concentration of free chlorine is important for monitoring the quality of water. In this study, we report a nanohybrid paper-based chemiresistive sensor that can be used with smartphones to detect free chlorine ions. The sensor was fabricated using a simple and standardized coating process. The graphene and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) nanohybrid paper-based sensing device exhibited a more stable and intuitive response to free chlorine than that exhibited by… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 16 publications
(26 citation statements)
references
References 19 publications
0
26
0
Order By: Relevance
“…The limit of detection (LOD) was calculated for the chemiresistor using Equation (4) of the calibration curve ( R 2 = 0.98), as shown in Figure 6 . The LOD of the sensor was defined as three times the standard deviation of a blank signal response [ 34 ]. The LOD of the chemiresistor for butanol gas was calculated to be 44.92 ppm.…”
Section: Resultsmentioning
confidence: 99%
“…The limit of detection (LOD) was calculated for the chemiresistor using Equation (4) of the calibration curve ( R 2 = 0.98), as shown in Figure 6 . The LOD of the sensor was defined as three times the standard deviation of a blank signal response [ 34 ]. The LOD of the chemiresistor for butanol gas was calculated to be 44.92 ppm.…”
Section: Resultsmentioning
confidence: 99%
“…An example of paper-based chemiresistive sensor for real-time monitoring of free chlorine is shown in Fig. 4b [112]. This sensor uses nanohybrid ink based on graphene and PEDOT: PSS.…”
Section: ) Interdigitated and Chemi-resistive Based Sensormentioning
confidence: 99%
“…There is indeed a concern that most environmental inspection assays could not meet outdoor onsite detection due to the requirements of complicated instruments and a relative long detection time [ 73 ]. With properties of low cost, easy operation, great portability, and easy disposal, paper-based sensors were found reliable to detect carbon dioxide [ 33 ], airborne particulate [ 74 ], volatile organic compounds [ 75 ] in the air, heavy metals [ 76 ], phosphates [ 77 ], inorganic element ions [ 78 , 79 , 80 ], nitrite [ 81 ], and nicotine [ 82 ] in the water.…”
Section: Paper-based Sensors For Environmental Quality Inspectionmentioning