2021
DOI: 10.3390/app11178234
|View full text |Cite
|
Sign up to set email alerts
|

Portable and Highly Versatile Impedance Meter for Very Low Frequency Measurements

Abstract: Electrical Impedance Spectroscopy (EIS) is a characterization technique that is gaining more and more importance in various fields of research and applications. The frequency range of investigation varies according to the type of application. In some fields (biology, medicine, energy) it is useful to be able to perform measurements at very low frequency values (down to a few mHz or even below). While impedance meters operating at frequencies in the range from a few tens of Hz up to a few MHz can be regarded as… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 49 publications
(69 reference statements)
1
5
0
Order By: Relevance
“…The values of the areal capacitance of the cells using electrodes developed from the PPy-GNP inks compare well with those obtained elsewhere using polyrrole and graphene based electrodes [39,40]. Impedance measurements were also performed on the test capacitors using the dedicated instrumentation discussed in [41]. In particular, we explored a very low frequency range, which was as low as 10 mHz with a 0 DC bias and a 20 mV amplitude for the AC test signals.…”
Section: Resultssupporting
confidence: 71%
See 1 more Smart Citation
“…The values of the areal capacitance of the cells using electrodes developed from the PPy-GNP inks compare well with those obtained elsewhere using polyrrole and graphene based electrodes [39,40]. Impedance measurements were also performed on the test capacitors using the dedicated instrumentation discussed in [41]. In particular, we explored a very low frequency range, which was as low as 10 mHz with a 0 DC bias and a 20 mV amplitude for the AC test signals.…”
Section: Resultssupporting
confidence: 71%
“…Impedance measurements were also performed on the test capacitors using the dedicated instrumentation discussed in [41]. In particular, we explored a very low frequency range, which was as low as 10 mHz with a 0 DC bias and a 20 mV amplitude for the AC test signals.…”
Section: Resultsmentioning
confidence: 99%
“…Especially for the measurement of impedance spectra at very-low-frequency values down to a few mHz or even below, many challenges should be solved. In this context, Scandurra et al [1] address the design, realization, and testing of a low-frequency impedance measurement platform. The realized system is portable, low-cost, and highly versatile.…”
Section: Measurement System Design For Field Applicationmentioning
confidence: 99%
“…Although most of the electromagnetic emissions were intentional and beneficial for society, the coexistence of such a huge number of electromagnetic sources resulted in the onset of electromagnetic interferences (EMIs), which should be carefully considered in order to avoid electromagnetic compatibility (EMC) issues where EMIs interfere with the proper operation of other electronic devices [ 4 , 5 ]. The scientific community has always been prudent concerning the possible effects on human health; several examples have seen the possible effects of EMIs on test equipment, both at low and high frequencies, and for various applications from the biomedical to the industrial field [ 6 , 7 , 8 , 9 , 10 , 11 , 12 , 13 ].…”
Section: Introductionmentioning
confidence: 99%