2014
DOI: 10.1039/c3an01963b
|View full text |Cite
|
Sign up to set email alerts
|

Polymeric plasticizer extends the lifetime of PVC-membrane ion-selective electrodes

Abstract: The nature of the plasticizer plays a pivotal role in the analytical performance of polymer membrane ion sensors. Conventional plasticizers suffer leaching or migration from the membrane and exudation, both of which could limit the lifetime of sensors based on plasticized membranes. Herein, we describe the use of polyester sebacate (PES), a model polymeric plasticizer, in the preparation of poly (vinyl chloride) (PVC) membrane ion-selective electrodes (ISEs) using valinomycin as ionophore. PVC membrane electro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
34
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 57 publications
(36 citation statements)
references
References 42 publications
(49 reference statements)
1
34
0
Order By: Relevance
“…7,21 Since tripodal squaramide ionophores had poor solubility in DOS (ε = 3.9), DBP (ε = 6.4) and DMP (ε = 8.5) with low dielectric constants, the more polar plasticizers NPOE (ε = 24) and FPNPE (ε = 50) were chosen. 7,21 Since tripodal squaramide ionophores had poor solubility in DOS (ε = 3.9), DBP (ε = 6.4) and DMP (ε = 8.5) with low dielectric constants, the more polar plasticizers NPOE (ε = 24) and FPNPE (ε = 50) were chosen.…”
Section: Optimization Of Electrode Performancementioning
confidence: 99%
“…7,21 Since tripodal squaramide ionophores had poor solubility in DOS (ε = 3.9), DBP (ε = 6.4) and DMP (ε = 8.5) with low dielectric constants, the more polar plasticizers NPOE (ε = 24) and FPNPE (ε = 50) were chosen. 7,21 Since tripodal squaramide ionophores had poor solubility in DOS (ε = 3.9), DBP (ε = 6.4) and DMP (ε = 8.5) with low dielectric constants, the more polar plasticizers NPOE (ε = 24) and FPNPE (ε = 50) were chosen.…”
Section: Optimization Of Electrode Performancementioning
confidence: 99%
“…Peaks were labeled in the spectra automatically via OMNIC soware (Thermo Electron Corporation, USA). 1 H Nuclear magnetic resonance (NMR) and 13 C NMR spectra of the products synthesized were performed on an AV-300 NMR spectrometer (Bruker Instrument Crop., Germany) at a frequency of 400 MHz. The process was carried out using CDCl 3 as solvent and tetramethylsilane (TMS) as an internal standard.…”
Section: Preparation Of Self-plasticizing Pvc Lmsmentioning
confidence: 99%
“…High Knormaljnormalz+pot and/or low -lognormalKjz+pot values indicate high selectivity towards the primary ions over the interfering ions. Recent publications in the field of ion‐selective sensors reveal that the acceptable values of -lognormalKjz+pot range from 0.1 to 7.5 in most cases . The values of -lognormalKjz+pot for the studied sensor are shown in Table S3.…”
Section: Resultsmentioning
confidence: 99%