2021
DOI: 10.1111/jerd.12805
|View full text |Cite
|
Sign up to set email alerts
|

Polymeric biomaterials maintained the esthetic efficacy and reduced the cytotoxicity of in‐office dental bleaching

Abstract: Evaluate the kinetics of hydrogen peroxide (H 2 O 2 ) degradation, esthetic efficacy and cytotoxicity of a bleaching gel with 35%H 2 O 2 applied on enamel previously covered or not with polymeric nanofibrillar scaffold (SNan), polymeric primer catalyst (PPol), and both. Standardized enamel/dentin discs (n = 128) obtained from bovine teeth were adapted to pulp chambers. After covering enamel with the polymeric products, the bleaching gel was applied for 45 min, establishing the following groups: G1: no treatmen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0
1

Year Published

2022
2022
2023
2023

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(16 citation statements)
references
References 48 publications
0
15
0
1
Order By: Relevance
“…The dentin surface of the E/DDs was manually regularized by wear with sandpapers of 400 and 600-granulations (T469-SF-Noton; Saint-Gobain Abrasivos Ltda, Jundiaí, SP, Brazil) until reaching the final thickness of 2.3 mm (Figure 1C). 10,11,28 After staining the standardized E/DDs with black tea, 11,28 they were homogeneously distributed into groups (Table 1). In G2, G4, G6, and G8, the total volume of 10 μl of PCP was applied with a micropipette for viscous products (Microman M50; Gilson Inc., Middleton, WI, USA), and the tip was used to distribute the bioproduct on the entire enamel surface.…”
Section: Assessment Of Oh • Production In the Bleaching Gelsmentioning
confidence: 99%
See 3 more Smart Citations
“…The dentin surface of the E/DDs was manually regularized by wear with sandpapers of 400 and 600-granulations (T469-SF-Noton; Saint-Gobain Abrasivos Ltda, Jundiaí, SP, Brazil) until reaching the final thickness of 2.3 mm (Figure 1C). 10,11,28 After staining the standardized E/DDs with black tea, 11,28 they were homogeneously distributed into groups (Table 1). In G2, G4, G6, and G8, the total volume of 10 μl of PCP was applied with a micropipette for viscous products (Microman M50; Gilson Inc., Middleton, WI, USA), and the tip was used to distribute the bioproduct on the entire enamel surface.…”
Section: Assessment Of Oh • Production In the Bleaching Gelsmentioning
confidence: 99%
“…The association of chemical substances capable of catalyzing H 2 O 2 seems to characterize a promising strategy to optimize in-office bleaching protocol. 11,12,28 The use of chemical activators derived from MnO has been reported by several researchers. 12,16,19 This metal oxide participates in H 2 O 2 catalysis, promoting its degradation and producing other ROS.…”
Section: Amount Of H 2 O 2 In the Extractsmentioning
confidence: 99%
See 2 more Smart Citations
“…Segundo Kenneth Markowitz (15) a sensibilidade ao clareamento dental pode ser devido a ativação direta de canais TRPA1 de fibras nervosas tipo C pulpares pela chegada de peróxido de hidrogênio (H2O2) não reagente (16). Nos últimos anos, estudos clínicos tem mostrado que além da concentração de H2O2, fatores como: tempo de aplicação dos géis e a espessura do esmalte e da dentina podem aumentar o efeito adverso do clareamento de consultório (17,18) Recentemente, foi lançado no mercado pela empresa brasileira MMOptics, um aparelho que irradia luz violeta a partir de uma fonte LED, com o comprimento de onda entre 405-410 nm. A emissão de luz nesse comprimento de onda coincide com o pico de absorção dos pigmentos, o qual interage seletivamente com os mais escuros, quebrando-os em cadeias menores, mais claras.…”
Section: Lista De Ilustraçõesunclassified