2007
DOI: 10.1002/ange.200700796
|View full text |Cite
|
Sign up to set email alerts
|

Polymer‐Based Elemental Tags for Sensitive Bioassays

Abstract: To identify a rare (e.g., diseased or foreign) cell in a complex mixture, or to understand the proteomic complexity[1,2] of cells, one needs to be able to measure simultaneously and quantitatively a large number of proteins or other biomarkers that may be present in a complex sample. This is a difficult task and is beyond the reach of current capabilities. To address a problem of this complexity, we have begun to develop a high-sensitivity assay[3-6] based upon elemental tags that will enable the simultaneous … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
56
0
1

Year Published

2009
2009
2021
2021

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 56 publications
(57 citation statements)
references
References 16 publications
0
56
0
1
Order By: Relevance
“…[1][2][3] Due to the purity of the metals and the mass resolution of ICP-MS, there is effectively no "spectral overlap." Since most of the elements used are not biologically relevant, there is also little background to cause "autofluoresence."…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…[1][2][3] Due to the purity of the metals and the mass resolution of ICP-MS, there is effectively no "spectral overlap." Since most of the elements used are not biologically relevant, there is also little background to cause "autofluoresence."…”
Section: Discussionmentioning
confidence: 99%
“…[2][3][4][5] Because of the metal purity and mass resolution of the mass cytometer, there is no "spectral overlap" from neighboring isotopes, and therefore no need for compensation matrices. Additionally, due to the use of lanthanide metals, there is no biological background and therefore no equivalent of autofluorescence.…”
Section: Introductionmentioning
confidence: 99%
“…Lou et al (2007) recently developed a new class of polymer-based elemental tags for ICP-MS detection. This water-soluble polymer contains multiple metalchelating ligands and offers the important advantages that each tag carries many copies of a given element, which greatly increases the assay sensitivity.…”
Section: Icp-ms Based Immunoassaymentioning
confidence: 99%
“…This water-soluble polymer contains multiple metalchelating ligands and offers the important advantages that each tag carries many copies of a given element, which greatly increases the assay sensitivity. It is possible to achieve detection limits at the order of parts per billion, which will allow the detection of cell surface markers with copy numbers as low as 100 (Lou et al, 2007).…”
Section: Icp-ms Based Immunoassaymentioning
confidence: 99%
“…For example, LCCC separates polymers based on structural differences, including functionality type distribution, composition distribution of copolymers, or differences in microstructure or topology independent of the molecular mass [32,42,43]. Approaches hyphenating LC to inductively coupled plasma (ICP)-MS have been used to quantify metal complexes within other crude, biological samples [44][45][46][47], including synthetic polymers [48].…”
mentioning