2004
DOI: 10.1002/elps.200305771
|View full text |Cite
|
Sign up to set email alerts
|

Polyelectrolyte‐modified short microchannel for cation separation

Abstract: Three alkali cations, potassium, sodium, and lithium, have been separated within 15 s in a 1 cm long polymer microchip. The separation microchannel is modified by a polycation, poly(allylammonium chloride), which makes the channel surfaces positively charged leading to a reversed electroosmotic flow (EOF) when compared to bare channels. Due to the decreased apparent mobility of the cations, the separation resolution is improved allowing the use of shorter channels.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
19
0

Year Published

2004
2004
2013
2013

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 28 publications
(21 citation statements)
references
References 32 publications
1
19
0
Order By: Relevance
“…3 Ratio hydroquinones 1a-d/␤-lactoglobulin A 3g=: 5 mM/5 M, from [68]. 4 The tagging yield was found to increase from 27 to 52% in 80 minutes of infusion. mass spectrum, the number of which corresponds exactly to the number of cysteines in the analyzed peptides only with 2-carboxymethylhydroquinone 1d [69,87].…”
Section: On-line Tagging Of Peptides and Application To Protein Identmentioning
confidence: 98%
See 1 more Smart Citation
“…3 Ratio hydroquinones 1a-d/␤-lactoglobulin A 3g=: 5 mM/5 M, from [68]. 4 The tagging yield was found to increase from 27 to 52% in 80 minutes of infusion. mass spectrum, the number of which corresponds exactly to the number of cysteines in the analyzed peptides only with 2-carboxymethylhydroquinone 1d [69,87].…”
Section: On-line Tagging Of Peptides and Application To Protein Identmentioning
confidence: 98%
“…For example, analytical separations such as capillary electrophoresis (CE) [3,4], two-dimensional electrokinetic separations [5], liquid chromatography (LC) [6], reaction and detection microchambers [7][8][9] have been implemented in the microfluidic format. More recently, analytical microfluidic systems have caught interest in the particular field of proteomics [10,11] because of the high analytical constraints demanded by this field, namely the low amount of sample usually available, the high complexity of the initial protein mixture, and the need for high-throughput analysis [12].…”
mentioning
confidence: 99%
“…Furthermore, it appears that quantitation is not a trivial task in microchip CE because of linearity [162,163] or limited resolution [164][165][166] problems.…”
Section: Microchip Technologymentioning
confidence: 98%
“…Nowadays, various polymeric materials [16] are used such as PDMS [17,18], PMMA [19,20], polycarbonate [21], poly(ethylenterephthalate) [22,23], thermoset polyester [24,25], and polyester toner [26,27], Zeonix/ Zeonor [28,29] or thermoplastic olefin polymer of amorphous structure [7,30,31].…”
Section: Introductionmentioning
confidence: 99%