2006
DOI: 10.1016/j.chroma.2006.07.058
|View full text |Cite
|
Sign up to set email alerts
|

Poly(cyclooctene)-based monolithic columns for capillary high performance liquid chromatography prepared via ring-opening metathesis polymerization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
26
0

Year Published

2007
2007
2015
2015

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 35 publications
(26 citation statements)
references
References 33 publications
0
26
0
Order By: Relevance
“…Buchmeiser and coworkers first developed various organic monolithic columns with inner diameter ranging from 50 m to 5 cm via ringopening metathesis polymerization for HPLC and CLC [87]. They also prepared the hybrid monolithic columns via ROMP by using cis-cyclooctene (COE), tris(cyclooct-4-enyl-1-oxy)methylsilane as monomers, 2-propanol and toluene as porogens, and RuCl 2 (Py) 2 (IMesH 2 )(CHC 6 H 5 ) (Py = pyridine, IMesH 2 = 1,3-dimesityl-4,5-dihydroimidazolin-2-ylidene) as initiator within the confines of 200 m id fused-silica capillary [87]. Recently, 5-norborn-2-enemethyl bromide (NBE-CH 2 Br) and tris(5-norborn-2-enemethoxy)methylsilane ((NBE-CH 2 O) 3 SiCH 3 ) (Fig.…”
Section: Other Polymerization Approaches Of Monomers Containing Silanesmentioning
confidence: 99%
“…Buchmeiser and coworkers first developed various organic monolithic columns with inner diameter ranging from 50 m to 5 cm via ringopening metathesis polymerization for HPLC and CLC [87]. They also prepared the hybrid monolithic columns via ROMP by using cis-cyclooctene (COE), tris(cyclooct-4-enyl-1-oxy)methylsilane as monomers, 2-propanol and toluene as porogens, and RuCl 2 (Py) 2 (IMesH 2 )(CHC 6 H 5 ) (Py = pyridine, IMesH 2 = 1,3-dimesityl-4,5-dihydroimidazolin-2-ylidene) as initiator within the confines of 200 m id fused-silica capillary [87]. Recently, 5-norborn-2-enemethyl bromide (NBE-CH 2 Br) and tris(5-norborn-2-enemethoxy)methylsilane ((NBE-CH 2 O) 3 SiCH 3 ) (Fig.…”
Section: Other Polymerization Approaches Of Monomers Containing Silanesmentioning
confidence: 99%
“…With the aid of such a column, proteins were separated for the first time at neutral pH by RP-CEC. Furthermore, Schlemmer et al [15] prepared monolithic columns for capillary HPLC via ringopening metathesis polymerization (ROMP) with ciscyclooctene (COE) and tris(cyclooct-4-enyl-1-oxy)methylsilane (CL) as monomers, 2-propanol and toluene as porogens, and RuCl 2 (Py) 2 (IMesH 2 )(CHC 6 H 5 ) (Py = pyridine, IMesH2 = 1,3-dimesityl-4,5-dihydroimidazolin-2-ylidene) as the initiator. With such a column, a mixture of six standard proteins, including ribonuclease A, insulin, albumin, lysozyme, myoglobin, and b-lactoglobulin, was separated successfully with a relative standard deviation (RSD) in retention times (t R ) ranging from 2.9 to 3.9%.…”
Section: Monoliths For Reversed Phase Chromatographymentioning
confidence: 97%
“…COE-based supports have a backbone structure with sec-allylic carbons, which have a higher oxidative stability than NBE-based monoliths with tert-allylic carbons. [17,26] Although the "living" nature of the polymer chains allows for greater reproducibility, the same basic principles that govern the pore sizes of free-radicalpolymerized monoliths also govern pore sizes in ROMP-based monoliths. Increasing the temperature leads to smaller pore sizes, and the ROMP monoliths are typically synthesized around 0 8C.…”
Section: Nbe-and Cis-coe-based Systemsmentioning
confidence: 98%