2021
DOI: 10.1021/acs.analchem.1c03087
|View full text |Cite
|
Sign up to set email alerts
|

Pocket-Size “MasSpec Pointer” for Ambient Ionization Mass Spectrometry

Abstract: Current ambient ionization sources for mass spectrometry (MS) are typically connected to gas cylinders, high-voltage supply, injection pump, and other accessory equipment, which hinder the popularization of MS in the field of on-site detection. Here, we developed a wireless pocket-size "MasSpec Pointer" (weights 65 g) based on arc discharge powered by a 3.7 V polymer Li battery for ambient ionization MS. A high voltage of 5600 V and 20 kHz was generated from the boost coil to penetrate air and form a plasma. T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
17
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(19 citation statements)
references
References 39 publications
2
17
0
Order By: Relevance
“…Thus, the energy barrier of epoxidation was lowered, and the rate constant was increased . As shown in Figure S6, two lipid isomers, oleic acid FA 18:1 (9Z) and cis-vaccenic acid FA 18:1 (11Z), were oxidized via BBIE, and the MS results were similar to the previous reports obtained using arc-induced and low-temperature plasma-induced epoxidations. , Therefore, the BBIE coupled with MS/MS can be used to distinguish UFA isomers.…”
Section: Resultssupporting
confidence: 81%
“…Thus, the energy barrier of epoxidation was lowered, and the rate constant was increased . As shown in Figure S6, two lipid isomers, oleic acid FA 18:1 (9Z) and cis-vaccenic acid FA 18:1 (11Z), were oxidized via BBIE, and the MS results were similar to the previous reports obtained using arc-induced and low-temperature plasma-induced epoxidations. , Therefore, the BBIE coupled with MS/MS can be used to distinguish UFA isomers.…”
Section: Resultssupporting
confidence: 81%
“…Figures depicting the design and appearance of the MasSpec Pointer (A‐D), the waveform of the pulsed high‐voltage of the device (E), and the use of use of the pointer (F). Reprinted with permission from Li et al., 2021 160 . Copyright 2021 American Chemical Society…”
Section: Applications Of Ambient Ionization Mass Spectrometrymentioning
confidence: 99%
“…Such techniques also necessitate highly specialized knowledge for operation, whereas widespread deployment of portable technologies would ideally be usable by nonexperts. In recent years, there has been a trend toward the development of simple "point-and-shoot" systems with automated data analysis to provide the user with simple real-time results (34,35).…”
Section: Future Prospectsmentioning
confidence: 99%