2004
DOI: 10.1515/cclm.2004.154
|View full text |Cite
|
Sign up to set email alerts
|

Plasma or serum samples: measurements of cardiac troponin T and of other analytes compared

Abstract: Conflicting data in the literature concern possible differences in the immunochemical measurement of cardiac troponins, either in plasma or in serum. In order to address this specific point, 96 serum and heparin-plasma pairs were obtained for cardiac marker measurement [cardiac troponin T (cTnT); myoglobin (Myo) and creatine kinase-MB isoenzyme (CK-MB)]; 29 additional "common" analytes were measured in 77 such samples. The cardiac markers were measured by electrochemiluminescence (Elecsys 2010, Roche); the oth… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2006
2006
2023
2023

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 27 publications
0
10
0
Order By: Relevance
“…Corin levels were measured in plasma [ 11 , 14 , 15 ] and serum [ 12 , 13 ] in different studies. Comparison of other cardiac markers, such as cardiac troponin T, creatine kinase-muscle/brain and myoglobin showed similar results in both fluids [ 30 , 31 ] which suggests that the sample type (plasma vs. serum) is unlikely to be the key factor associated with different findings among the studies. Protease activity in blood samples might also influence the measured corin levels, but protease inhibition in blood samples was not specified in these studies [ 12 14 ].…”
Section: Discussionmentioning
confidence: 82%
“…Corin levels were measured in plasma [ 11 , 14 , 15 ] and serum [ 12 , 13 ] in different studies. Comparison of other cardiac markers, such as cardiac troponin T, creatine kinase-muscle/brain and myoglobin showed similar results in both fluids [ 30 , 31 ] which suggests that the sample type (plasma vs. serum) is unlikely to be the key factor associated with different findings among the studies. Protease activity in blood samples might also influence the measured corin levels, but protease inhibition in blood samples was not specified in these studies [ 12 14 ].…”
Section: Discussionmentioning
confidence: 82%
“…Plasma has its own set of areas for concern, for example, problem of adequate mixing of blood with anticoagulants, difference in result values for some analytes when measured in serum or plasma, especially potassium and lactate dehydrogenase, thus requiring changes in reference intervals [5]. With its inherent known limitations particularly in the more recent reports of issues with cardiac markers, plasma may not be the specimen of choice [6–9]. …”
Section: Introductionmentioning
confidence: 99%
“…This is of critical importance due to the heavy reliance on diagnostic and prognostic decision-making in the initial hours after onset of chest pain. More recently, in studies for both cTnT 76 and cTnI, 77 similar in vitro concentrations have been reported in serum and plasma; however, in the study by Wang et al 77 citrate anticoagulant rather than heparin was used for cTnI determination. More importantly, in the 96 matched serum plasma samples studied by Dominici et al 76 there were no misclassifications, if plasma was used instead of serum.…”
Section: Effects Of Anticoagulant Sample Tubes On Cardiac Troponin Asmentioning