2008
DOI: 10.1063/1.2986520
|View full text |Cite
|
Sign up to set email alerts
|

Plasma dynamics during relativistic S-band magnetron operation

Abstract: Results of a time- and space-resolved spectroscopic research studies of an S-band relativistic magnetron generating 1.5×108 W microwave power at f=2950 MHz, powered by a linear induction accelerator (450 kV, 4 kA, 150 ns), are presented. The cathode plasma electron density and temperature were obtained by analyzing Hα and Hβ hydrogen Ballmer series and carbon C II and C III ion spectral lines and the results of collision radiative modeling. It was shown that the microwave generation is accompanied by a signifi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 26 publications
(4 citation statements)
references
References 14 publications
0
4
0
Order By: Relevance
“…The application of the HV pulse to the cathode leads to the formation of an explosive emission plasma 30 serving as a source of electrons accelerated towards the anode. During 20 ns of the HV pulse duration, the expansion of the plasma towards the anode along the magnetic field can be estimated to be 2 mm, 31 and indeed the AC 3 mm gap did not short. Typical waveforms of the diode current and voltage are shown in Fig.…”
Section: Experimental Setup and Diagnosticsmentioning
confidence: 88%
“…The application of the HV pulse to the cathode leads to the formation of an explosive emission plasma 30 serving as a source of electrons accelerated towards the anode. During 20 ns of the HV pulse duration, the expansion of the plasma towards the anode along the magnetic field can be estimated to be 2 mm, 31 and indeed the AC 3 mm gap did not short. Typical waveforms of the diode current and voltage are shown in Fig.…”
Section: Experimental Setup and Diagnosticsmentioning
confidence: 88%
“…La-doping has been shown to reduce the c/a ratio of BF-PT from 1.10 down to 1.01. [14][15][16][17][18] Therefore, BF-PT with eight different La-contents was utilized as a model system to study the influence of c/a ratio on the domain switching behavior of ferroelectrics. As domain switching is affected by the distance to the respective morphotropic phase boundary ͑MPB͒, the BF/PT ratio was readjusted to the altered Lacontent to assure that all materials are at an MPB.…”
Section: Introductionmentioning
confidence: 99%
“…insulated) by the applied or induced magnetic field to generate high-power microwaves (Benford et al 2015). However, as the devices increase in power and become more compact, plasma generation is unavoidable as the current density in the system increases (Hadas et al 2008). Although low-frequency plasma oscillations are not well-studied due to the short pulse operation, it can be seen from figure 6(b) that the partially magnetised plasma is unstable in such configurations, similar to the Penning discharge.…”
Section: Cylindrical Magnetronmentioning
confidence: 99%